APAR status
Closed as program error.
Error description
ERROR DESCRIPTION: When a Radio Button Group control is dragged to the application canvas in Application Designer, although the Text Alignment is LEFT the header is not justified to the left. As a reference per Dev request, please consider existing APAR IV94884. PROBLEM: When a Radio Button Group control is dragged to the application canvas in Application Designer, although the Text Alignment is LEFT the header is not justified to the left. This is not a consistent issue that can be replicated every time, but it happens and there is no way to adjust the header alignment in the application. As a reference per Dev request, please consider existing APAR IV94884. STEPS TO REPRODUCE: This case was replicated at: http://mxbuild-iot-1.fyre.ibm.com:10268/maximo Cloned the SR app and created the ZZ_MATLTRANSFER application. Then created the following Radio Button Group controls in the Material Transfer tab , from the control pallete (all of them have the Text Alignment property set to Left) : Control ID= 1606402175317 Label= ROBERTO TEST1 *for some reason this one is incorrectly label aligned to the right Control ID= 1606402228389 Label= ROBERTO TEST2 *for some reason this one is correctly label aligned to the right Control ID= 1606402309884 Label= ROBERTO TEST3 *this one is correctly label aligned to the left Steps are : Open Maximo as maxadmin Go to Application Designer application Open an application canvas like PR application Open the Control Pallette and drag a Radio Button Group control You will see that the Radio Group Control header will remain to the right instead of left CURRENT ERRONEOUS RESULT: Although the Text Alignment is LEFT the header is not justified to the left. EXPECTED RESULT: The header is justified to the left. ENVIRONMENT (SYSTEM INFO): Tivoli's process automation engine 7.6.1.2-IFIX20200921-1601 Build 20200715-0100 DB Build V7612-284 HFDB Build HF7612-07 IBM Maximo Asset Management Work Centers 7.6.0.4 Build 20200715-0100 DB Build V7604-119 IBM Tpae Integration Framework 7.6.1.2 Build 20200615-2330 DB Build V7612-11 IBM Maximo Asset Management 7.6.1.2 Build 20200715-0100 DB Build V7611-01 IBM Maximo for Oil and Gas 7.6.1.0-20200805-1125 Build 20161020-0803 DB Build V7610-139 HFDB Build HF7610-56 IoT Connection Utility 7.6.0.3 Build 20200701-1409 DB Build V7603-32
Local fix
NA
Problem summary
**************************************************************** * USERS AFFECTED: * * N/A * **************************************************************** * PROBLEM DESCRIPTION: * * RADIO BUTTON GROUP CONTROL TEXT ALIGNMENT IS LEFT BUT THE * * HEADER IS NOT JUSTIFIED TO THE LEFT. * ****************************************************************
Problem conclusion
Fixed in labels-vertical.css
Temporary fix
Comments
APAR Information
APAR number
IJ30420
Reported component name
SYSTEM CONFIG
Reported component ID
5724R46S1
Reported release
761
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2021-01-21
Closed date
2021-07-14
Last modified date
2021-07-14
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SYSTEM CONFIG
Fixed component ID
5724R46S1
Applicable component levels
[{"Line of Business":{"code":"LOB59","label":"Sustainability Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761"}]
Document Information
Modified date:
15 July 2021