Error description

  • After upgrade from Maximo 7.6.0.9 to 7.6.1.1, Integrity Checker
    raises the following WARNING:
    
    BMXAA0442W -- Warning -
    BMXAA0469W -- There was no unique index found for the primary
    key sequence on the table. Determine whether the table requires
    an index for the primary key column sequence.
    SKDTEMPLATES
    
    An
    Index named SKDTEMPLATES_NDX1 does exist for the Primary Key
    Columns but the "Enforce Uniqueness?" checkbox is not checked.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users of the Scheduler Tool Tip Manager application.         *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * SKDTEMPLATES OBJECT MISSING UNIQUE INDEX ON PRIMARY KEY      *
    * COLUMNS                                                      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • A code fix has been made.
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ26746

  • Reported component name

    MAXIMO ASST MGM

  • Reported component ID

    5724R46AM

  • Reported release

    761

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-07-31

  • Closed date

    2020-08-03

  • Last modified date

    2020-08-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • MAXIMO
    

Fix information

  • Fixed component name

    MAXIMO ASST MGM

  • Fixed component ID

    5724R46AM

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"IBM Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"761","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
05 August 2020