IBM Support

IJ24740: CRASH FROM GC AFTER CALLING WRITE BARRIER

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Error Message: A GPF is received when some JIT method is
    compiled.
    .
    Stack Trace: The native stack trace may looks like this:
    #13 <signal handler called>
    #14 isObjectInEvacuateMemory ()
    #15 MM_StandardAccessBarrier::preObjectRead ()
    #16 0x00007f60557c5863 in
    MM_ObjectAccessBarrier::mixedObjectReadObject ()
    #17 0x00007f6055e52bb8 in
    TR_J9MutableCallSite::findCallSiteTarget()
    .
    

Local fix

  • This issue can be worked around by using -Xgcpolicy:gencon
    

Problem summary

  • The write barrier code assumes GC policy Gencon but it might
    fail with Optthruput or Optavgpause.
    

Problem conclusion

  • The JVM has been updated so that GC checks for GC policy for
    correct action.
    
    .
    This APAR will be fixed in the following Java Releases:
       8    SR6 FP5   (8.0.6.5)
    .
    Contact your IBM Product's Service Team for these Service
    Refreshes and Fix Packs.
    For those running stand-alone, information about the available
    Service Refreshes and Fix Packs can be found at:
               https://www.ibm.com/developerworks/java/jdk/
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ24740

  • Reported component name

    J9 COMMON CODE

  • Reported component ID

    620700127

  • Reported release

    270

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-05-04

  • Closed date

    2020-05-04

  • Last modified date

    2020-05-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    J9 COMMON CODE

  • Fixed component ID

    620700127

Applicable component levels

  • R270 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSNVBF","label":"Runtimes for Java Technology"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"7.0","Line of Business":{"code":"LOB36","label":"IBM Automation"}}]

Document Information

Modified date:
21 February 2022