Error description
Even with setting 1 for mxe.crontask.runonschedule, a crontask instance is fired right after being activated. STEPS TO REPRODUCE: Although this is originally reported in MAM 7.6.0.9, it can be reproduced even in MAM 7.6.1.1 with the following scenario. 1) From Cron Task Setup, open JMSQSEQCONSUMER. 2) Confirm "LASTRUN" value for SEQQIN instance is null. 3) For SEQQIN instance, set the following value for "Schedule" field so that it will run at 19:00 every day. 1d,0,00,19,*,*,*,*,*,* Then check both "Active?" and "Keep History?" check boxes and save the changes. 4) After selecting "Reload Request" from More Actions, confirm that SEQQIN instance is fired at 18:37 unexpectedly. This is the problem. 5) 23 minutes later, confirm SEQQIN instance is fired again at 19:00 as scheduled. Although JMSQSEQCONSUMER is used in this scenario as an example, this can happen with any crontasks. EXPECTED RESULT: The crontask instance should not be fired at 18:37 because it is scheduled to be fired at 19:00. PRODUCT VERSION: Maximo Asset Management 7.6.0.9
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * MAXIMO * **************************************************************** * PROBLEM DESCRIPTION: * * CRONTASK INSTANCE IS FIRED RIGHT AFTER BEING ACTIVATED * ****************************************************************
Problem conclusion
This was fixed by IJ01148.The fix for this APAR is contained in the following maintenance package:The fix for this APAR is contained in the following maintenance package: | release\fix pack for Release 7.6.1.3 Product
Temporary fix
Comments
APAR Information
APAR number
IJ22159
Reported component name
SYSTEM CONFIG
Reported component ID
5724R46S1
Reported release
760
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2020-01-19
Closed date
2021-07-01
Last modified date
2021-07-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SYSTEM CONFIG
Fixed component ID
5724R46S1
Applicable component levels
[{"Type":"MASTER","Line of Business":{"code":"LOB59","label":"Sustainability Software"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"IBM Maximo Asset Management"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All Versions"}]
Document Information
Modified date:
02 July 2021