IBM Support

IJ21488: CRASH DURING JIT COMPILATION

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Error Message: The JVM exits unexpectedly, with crash data
    written as per operating system and JVM configuration.
    .
    Stack Trace: The javacore will show a crash in module libj9jit,
    and one or more of the registers will hold the 32 bit value for
    -1 (00000000FFFFFFFF). Use of a native debugger will show the
    crashing method is
    TR_J9VMBase::getResolvedVirtualMethod(TR_OpaqueClassBlock*, int,
    bool), called during inlining.
    .
    

Local fix

  • The method that was being compiled can be excluded from JIT
    compilation. e.g. if the method was in package a.b, class C and
    called 'method':
    -Xjit:exclude={a/b/C.method(*},dontInline={a/b/C.method(*}
    

Problem summary

  • An error in the JIT compiler resulted in an incorrect vtable
    offset being passed to getResolvedVirtualMethod.
    

Problem conclusion

  • The JIT has been modified so that a valid vtable offset is
    stored in all cases.
    For more details:
    https://github.com/eclipse/openj9/pull/6993
    .
    This APAR will be fixed in the following Java Releases:
       8    SR6 FP5   (8.0.6.5)
    .
    Contact your IBM Product's Service Team for these Service
    Refreshes and Fix Packs.
    For those running stand-alone, information about the available
    Service Refreshes and Fix Packs can be found at:
               https://www.ibm.com/developerworks/java/jdk/
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ21488

  • Reported component name

    JIT

  • Reported component ID

    620700124

  • Reported release

    130

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-12-06

  • Closed date

    2019-12-06

  • Last modified date

    2019-12-06

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    JIT

  • Fixed component ID

    620700124

Applicable component levels

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSC9HBA","label":"Just In Time (JIT) Compiler"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"130","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: