IBM Support

IJ18303: CONNECTIONS NOT CLOSING CAUSING INACTIVE CONNECTION BUILDUP

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

 

APAR status

  • Closed as program error.

Error description

  • Maximo is not closing connections properly, which can cause a
    buildup of long running and inactive connections in the
    database.
    
    STEPS TO REPRODUCE:
    Allow Maximo to run for an extended period of time.
    
    CURRENT ERRONEOUS RESULT:
    Connections will continuously buildup, causing a strain on the
    database.
    
    EXPECTED RESULTS:
    Maximo should close connections properly.
    
    REPORTED IN VERSION:
    Tivoli's process automation engine 7.6.1.1 Build 20190514-1348
    DB Build V7611-365
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * all users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * CONNECTIONS NOT CLOSING CAUSING INACTIVE CONNECTION BUILDUP  *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * add finally block to close database connection               *
    ****************************************************************
    

Problem conclusion

  • the block was moved to fix MT issue which cause breaking in
    regular on-prem enviornmnt
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ18303

  • Reported component name

    SYSTEM PERFORMA

  • Reported component ID

    5724R46PF

  • Reported release

    760

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-08-12

  • Closed date

    2019-08-22

  • Last modified date

    2019-08-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    SYSTEM PERFORMA

  • Fixed component ID

    5724R46PF

Applicable component levels

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCHPP5","label":"System Related"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"760","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
22 August 2019