APAR status
Closed as program error.
Error description
The time zone rules application is currently doing the time zone conversion in the wrong direction. In the example below we are using Karachi as an example, there is a 10 hour difference between where the server is and Karachi. STEPS TO REPRODUCE: Use an environment with application server running in EST (GMT -5). 1) Create a new Location, TIME. 2) Set status to OPERATING. 3) Associate time zone of Asia/Karachi. 4) Create a new Time Zone Rule. Process: PMWOGEN, Process Rule: LOCATIONS. 5) Create a new PM. Location: TIME, Target Start Time: 1 PM. 6) Set status to ACTIVE. 7) Generate Workorders. Uncheck "Use Frequency Criteria", and generate only 1. 8) Set user time zone to US/Eastern, log out, and log in. 8) Open the newly generated WO, and view the Target Start Date. Expected Result: Target Start Date has a time of 3:00 AM (1:00 PM - 10 hours). Current Erroneous Result: Target Start Date has a time of 11:00 PM (1:00 PM + 10 hours). There is a 10 hour difference between Asia/Karachi and US/Eastern. The time zone conversion is being performed in the wrong direction in this case. PRODUCT VERSION: Issue was reproduced against Maximo 7.6.0.9.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users in Preventative Maintenance who have Time Zone Rules * * configured. * **************************************************************** * PROBLEM DESCRIPTION: * * For certain pairs of object and server time zones, the Time * * Zone Rules functionality may incorrectly perform the * * conversion from object to server time zone. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The fix for this APAR is included in the following package: | Release 7.6.1.1 of Base Services.
Temporary fix
Comments
APAR Information
APAR number
IJ12671
Reported component name
ADMINISTRATION
Reported component ID
5724R46A1
Reported release
760
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2019-01-11
Closed date
2019-03-28
Last modified date
2019-03-28
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
ADMINISTRATION
Fixed component ID
5724R46A1
Applicable component levels
R760 PSY
UP