Error description
When a PowerHA Resource Group includes NFS exports which have a path that is a subset of another exported path, then the exportfs command on RG acquisition will fail.
Local fix
None, except avoid exporting directories which have a path subset of another.
Problem summary
When a PowerHA Resource Group includes NFS exports which have a path that is a subset of another exported path listed in /usr/es/sbin/cluster/etc/exports, then the exportfs command on RG acquisition will fail. For example, the following entries will cause the issue: /export/data /export/data/backup When PowerHA configures NFS for /export/data, it will mistakenly include the arguments for both of the above paths.
Problem conclusion
Correct the grep command so that it can differentiate sub paths.
Temporary fix
None, except avoid exporting directories which have a path subset of another
Comments
APAR Information
APAR number
IJ10507
Reported component name
POWERHA SYSMIR
Reported component ID
5765H3900
Reported release
722
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Submitted date
2018-10-15
Closed date
2018-10-29
Last modified date
2018-10-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
POWERHA SYSMIR
Fixed component ID
5765H3900
Applicable component levels
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"722","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSXU4N","label":"PowerHA SystemMirror Enterprise Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"722","Edition":"","Line of Business":{"code":"LOB08","label":"Cognitive Systems"}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSLM9V","label":"PowerHA SystemMirror Standard Edition for AIX"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"722","Edition":"","Line of Business":{"code":"LOB57","label":"Power"}},{"Business Unit":{"code":"BU008","label":"Security"},"Product":{"code":"SGL4G4","label":"PowerHA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"722","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
19 October 2021