APAR status
Closed as program error.
Error description
STEPS TO REPRODUCE: 1) Use the Application Designer application to clone the WOTRACK application to WOTRACK_EV, setting the isMobile flag and choosing the default viewport 2) Use the Security Groups applications to verify that maxadmin has access to the WOTRACK_EV application 3) Use Prfile -> Default Information to set Locale = es_MX 4) Add a Favourite Applications portlet to a Start Center for maxadmin 5) Add WOTRACK_EV to the list of applications in this portlet and tick Is Mobile 6) Log off and on 7) Click on WOTTACK_EV in the Favourite Applications portlet 8) Select any Work Order 9) Select a date/time for Target Start using the calendar picker 9) Click OK and tab out of the Target Start field RESULTS: Error message in browser: BMXAA4144E - The date/time format is not valid. Make sure the date/time is specified in a valid format supported by the current locale setting. More information The selected date/time is not saved EXPECTED RESULTS: The selected date/time is saved (if it is valid) PRODUCT VERSION: Tivoli's process automation engine 7.6.0.8-IFIX20180130-1210 Build 20170512-0100
Local fix
Enter the date/time manually e.g. 04-jul-18 04:52 PM
Problem summary
**************************************************************** * USERS AFFECTED: * * n/a * **************************************************************** * PROBLEM DESCRIPTION: * * there is a bug when I add date/time using date picker in the * * workorder application * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
fixed in the datepicker.js
Temporary fix
Comments
APAR Information
APAR number
IJ07466
Reported component name
SYSTEM CONFIG
Reported component ID
5724R46S1
Reported release
760
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-07-02
Closed date
2018-09-27
Last modified date
2018-09-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SYSTEM CONFIG
Fixed component ID
5724R46S1
Applicable component levels
R761 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSLKT6","label":"IBM Maximo Asset Management"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"760","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]
Document Information
Modified date:
27 September 2018