IBM Support

IJ02708: NCO_G_OBJSERV_BI PROCESS CRASHED WITH CORE WHEN TERMINATING THE PROCESS

Direct links to fixes

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • L3 analyzed the symtom and provided the comment below.
    "Based on the fact that shutting down PA with the "-option
    STOP" will also stop managed processes, and based on the
    location of the thread in the core (sending a GW watch to the
    ObjectServer) I suspect the ObjectServer has exited before the
    gateway had a chance to send its GW watch, and the connection
    was marked dead but not handled correctly in doing so,
    resulting in the crash.
     Based on the code, it looks like the session being used is
    garbage, so the pointers being used are invalid. This will be
    the result of the session being de-allocated and the memory
    reused, and so filled with garbage as far as session data is
    concerned. It is noted in the code that a GW watch is being
    sent when the backup ObjectServer connection is lost, but with
    no primary connection to send it to (which is also lost) the
    result is this crash.
    This is definitely a bug, but the consequences are minimal in
    the circumstances, as it appears everything is being shut down
    anyway."
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users of the OMNIbus bidirectional gateway                   *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * On shutdown of the gateway, the gateway could crash while    *
    * attempting to send a gateway watch event. Alternatively, the *
    * gateway could change the ActingPrimary of the backup         *
    * ObjectServer, resulting in resync problems upon restart.     *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Apply the maintenance vehicles listed in the Problem         *
    * Conclusion.                                                  *
    ****************************************************************
    

Problem conclusion

  • The fix for this APAR is contained in the following maintenance
    packages:
     | fix pack | 8.1.0-TIV-NCOMNIbus-FP0022
    

Temporary fix

Comments

APAR Information

  • APAR number

    IJ02708

  • Reported component name

    NC/OMNI GTWY (B

  • Reported component ID

    5724O73OS

  • Reported release

    100

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-12-17

  • Closed date

    2019-11-27

  • Last modified date

    2019-11-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    NC/OMNI GTWY (B

  • Fixed component ID

    5724O73OS

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSSHTQ","label":"Tivoli Netcool\/OMNIbus"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"100","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
17 March 2023