IBM Support

II03665: VSEPT R224 REFRESH INFORMATION.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as canceled.

Error description

  • PRODUCT        COMPID         RELEASE
    VSE/PT        5796PLQ00        R224
    .
    THE VSE/PT R224 REFRESH TAPE IS A REFRESH OF THE VSE/PT PRODUCT.
    ALL THE HIPER APARS AND A SELECTION OF OTHER APARS TAKEN AGAINST
    VSE/PT ARE ON THIS REFRESH.  THE VSE/PT REFRESH WAS SHIPPED FROM
    I.S.D. TO ALL CUSTOMERS OF RECORD.  THE SHIPMENT WAS COMPLETED
    FOR ALL DOMESTIC (U.S.A.) CUSTOMERS ON 11/18/88.  WORLD TRADE
    LIBRARIES IN BRAZIL, JAPAN, COPENHAGEN, AUSTRALIA, MEXICO,
    CANADA, AND ARGENTINA WERE ALSO SHIPPED THIS VSE/PT R224 REFRESH
    TAPE FOR DISTRIBUTION TO WORLD TRADE CUSTOMERS.  THE REFRESH
    WAS SHIPPED TO THESE LIBRARIES ON 11/18/88, AND SHOULD ARRIVE
    NO LATER THAN 12/9/88.  AT THAT TIME, ANY WORLD TRADE CUSTOMER
    OF RECORD WILL BE SHIPPED THE REFRESH TAPE.  ANY CUSTOMER
    PURCHASING VSE/PT FOR THE FIRST TIME WILL RECEIVE THE REFRESH
    TAPE INSTEAD OF THE OLD (BASE) PRODUCT TAPE.
       APARS INCLUDED ON THE VSE/PT REFRESH ARE GB00016, GB00110,
    GB00064, GB00092, GB00093, GB00094, GB00096, GB00097, GB00098,
    GB00099, GB00100, GB00102, GB00103, GB00104, GB00106, GB00108,
    GB00109, GB00115, GB00116, GB00118, GB00119, GB00121, GB00123,
    GB00128, GB00129, GB00131, GB00133, GB00134, GB00135, GB00137
    GB00141, GB00147, AND GB00101.
       THE REFRESH IS INSTALLED JUST AS IF IT WERE A NEW PRODUCT
    INSTALLATION.  PLEASE REFER TO AND FOLLOW THE INSTALL
    PROCEDURE IN THE VSE/PT PROGRAM DESCRIPTION/OPERATIONS MANUAL
    (PDOM) (SH20-2171-6), PAGE 151.  THE $$$VSEPT MODULE IS NO
    LONGER NEEDED, AND IS NOT ON THE REFRESH TAPE.  IF YOUR
    VSE/PT PDOM HAS NOT BEEN UPGRADED WITH THE JULY 1, 1988 TNL,
    ALL JCL ON PAGE 152 CAN BE IGNORED.  ***WARNING*** :
    IF THE JOB ON PAGE 152 WHICH IS USED TO LOAD THE $$$VSEPT
    PHASE IS ACCIDENTALLY RUN, IT MAY CAUSE AN I/O LOOP OR A
    CPU LOOP IN THE START-UP PARTITION AND THE LOOP CANNOT
    BE CANCELLED.
       AFTER INSTALLATION IS COMPLETE, VERIFICATION THAT THE
    VSE/PT R224 REFRESH CODE IS INSTALLED (INSTEAD OF THE BASE
    CODE - VSE/PT R224 WITHOUT APARS ALREADY APPLIED) CAN BE DONE
    BY DOING THE FOLLOWING:
       1.  RUN A LIBR LIST OF THE DOSVSESA PHASE.
       2.  IF AT X'00885C' YOU FIND X'47201020',
            YOU HAVE THE 'REFRESH' CODE INSTALLED.
       3.  IF AT X'00885C' YOU FIND X'47000000',
            YOU HAVE THE 'REFRESH' INSTALLED AND GB00144 APPLIED.
       4.  IF AT X'008874' YOU FIND X'47201020'
            YOU HAVE THE 'BASE' CODE INSTALLED.
    IF THE ABOVE PROVES THAT BASE CODE IS INSTALLED, THE VSE/PT
    R224 REFRESH SHOULD BE ORDERED FROM THE S.E. (SEE BELOW).
       IF THE ALREADY APPLIED FIXES ON THE REFRESH ARE ATTEMPTED
    TO BE APPLIED AGAIN (SOMEONE NOT REALIZING THEY HAVE THE
    REFRESH APPLIED), THE CUSTOMER WILL NOT BE ABLE TO VERIFY THE
    CORRECT CODE AT THE LOCATION ON THE PRE-REFRESH APARS.
    ( CAN NOT VERIFY FIX - FIXES ). THE ABOVE DESCRIBED ALGORITHM
    FOR VERIFYING 'BASE' OR 'REFRESH' CODE SHOULD BE USED.
       IF DOMESTIC CUSTOMERS FOR ANY REASON HAVE NOT BEEN SHIPPED
    THE VSE/PT REFRESH, THEY CAN CONTACT THEIR S.E. OR MARKETING
    REPRESENTATIVE.  THEIR S.E. OR MARKETING REP SHOULD CALL THE
    I.S.D. ORDER CONTROL AREA ON TIE LINE 8-528-7860 REQUESTING
    THE REFRESH.
       BELOW IS A LIST OF THE APARS THAT ARE NOT ON THE REFRESH
    AND SHOULD BE APPLIED TO VSE/PT R224.  THEY ARE:
         GB00023 - SYSTEM ACTIVITY REPORT (DOSVSESA)
         GB00029 - SYSTEM ACTIVITY REPORT (DOSVSESA)
         GB00144 - SYSTEM ACTIVITY REPORT (DOSVSESA)
         GB00146 - RUN ACTIVITY REPORT  (DOSVSERA)
         GB00154 - DASD ACTIVITY REPORT (DOSVSEDA)
         GB00155 - DASD ACTIVITY REPORT (DOSVSEDA)
         GB00156 - DASD ACTIVITY REPORT (DOSVSEDA)
         GB00158 - EXCEPTION REPORT     (DOSVSEEX)
         GB00018 - VSE/PT DOSVSESP PHASE(DOSVSESP)
    .
      ALL NEW APARS WILL BE TAKEN AGAINST THE REFRESH CODE. THESE
    APARS CAN BE FOUND IN THE 'PA' LIBRARY.
       THERE ARE TWO TNL'S AGAINST THE VSE/PT PROGRAM
    DIRECTORY/OPERATIONS MANUAL (PDOM) (SH20-2171-6).  IF THE
    TNL'S ARE NOT SHIPPED WITH THE VSE/PT PDOM, CONTACT YOUR
    S.E. OR MARKETING REP. TO HAVE THEM ASSIST IN ACQUIRING THE
    TNL'S.  THE FOLLOWING ARE THE DATES AND TNL NUMBERS:
        TNL NUMBER         DATE RELEASED
        ----------         -------------
        SN28-4666-0        JULY 1, 1988
        SN29-6000-0        SEPTEMBER 1, 1988
    .
    VSE/PT R230 IS NOW AVAILABLE.  CUSTOMERS RUNNING VSE/SP
    SHOULD UPGRADE TO THIS NEW LEVEL.  CUSTOMERS RUNNING
    VSE/AF VERSION 1 SHOULD STAY AT VSE/PT R224 REFRESH AS
    THERE IS NO DOSVSEAF MODULE INCLUDED IN VSE/PT R230.
    .
    

Local fix

  • INFO ONLY:  COMPONENT 5796PLQ00 LEVEL 224
    

Problem summary

Problem conclusion

Temporary fix

Comments

  • THIS IS AN INFORMATION APAR FOR VSE/PT R224 REFRESH.
    

APAR Information

  • APAR number

    II03665

  • Reported component name

    PA LIB INFO ITE

  • Reported component ID

    INFOPALIB

  • Reported release

    001

  • Status

    CLOSED CAN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    1988-12-08

  • Closed date

    1988-12-09

  • Last modified date

    1990-06-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19N","label":"APARs - OS\/390 environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG32M","label":"APARs - VSE\/ESA environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":null,"label":null},"Product":{"code":"SG19O","label":"APARs - MVS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSSN3L","label":"z\/OS Communications Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG27M","label":"APARs - z\/VM environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"001","Edition":"","Line of Business":{"code":"LOB16","label":"Mainframe HW"}}]

Document Information

Modified date:
13 December 2020