Fixes are available
APAR status
Closed as program error.
Error description
Personal Communications v6.0.7 5250 connection When the customer try to display the screen which had gridline, the 5250 session is input inhibit status. It seems that the trace shows i5 sent SOCKET ERROR to PCOM when the client sends a lot of inbound data.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All DBCS (double byte character set) 5250 * * session users * **************************************************************** * PROBLEM DESCRIPTION: Under a DBCS environment, PCOM 5250 * * display session containing large grid * * data may crash when SAVE command is * * received. * **************************************************************** * RECOMMENDATION: * **************************************************************** Under a DBCS environment, IBM Personal Communications 5250 display session containing large grid data may crash when SAVE command is received. The problem could happen irrespective of the screen size set. When the SAVE command is received from the host, the telnet module allocates a buffer to save the received data. If the size of the data is more than the allocated buffer size, internal memory gets corrupted due to buffer overrun. This subsequently causes PCSCM.EXE process to terminate abnormally.
Problem conclusion
PCSTLNET.DLL buffer size was increased to ensure that there is sufficient space to accommodate large data received from the host. Fix scheduled for PCOM 6.0.12 Refresh Pack
Temporary fix
Comments
APAR Information
APAR number
IC99486
Reported component name
PCOMM V5 COMBO-
Reported component ID
5639I700J
Reported release
601
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-02-19
Closed date
2014-10-15
Last modified date
2014-10-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
PCSTLNET
Fix information
Fixed component name
PCOMM V5 COMBO-
Fixed component ID
5639I700J
Applicable component levels
R601 PSY
UP