Fixes are available
APAR status
Closed as program error.
Error description
If there is a network connection error on the Front Side Handler of a Multi-Protocol Gateway service, the error path might result in a restart during multi-step processing.
Local fix
Problem summary
The fix prevents DataPower B2B appliance from restarting when a network error occurs on a front network interface while running an ebMS processing policy. Customers who use ebMS protocol on DataPower XB60 and XB62 for business document exchange might see this problem.
Problem conclusion
Fix available in 5.0.0.12 and 6.0.0.4. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IC98240
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
500
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-12-10
Closed date
2013-12-18
Last modified date
2014-01-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R500 PSY
UP
R600 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date: