APAR status
Closed as program error.
Error description
Sqlexec threads can get stuck in an infinite for loop in need_usr_write_ticket() Stack trace for the hung threads: cmprstr() need_usr_write_ticket() get_sysdbprocids() ddopen() dbopen() find_db() sqopendb() dodatabase() chkarg4() sqmain() listen_verify() spawn_thread() th_init_initgls() startup() or need_usr_write_ticket() get_sysdbprocids() ddopen() dbopen() find_db() sqopendb() excommand() sq_execute() sqmain() listen_verify() spawn_thread() th_init_initgls() startup() The loop is in need_usr_write_ticket(). To hit this code a sysdbopen() procedure must be defined.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Those using sysdbopen / sysdbclose * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IDS-11.70.xC8 * ****************************************************************
Problem conclusion
Problem Fixed In IDS-11.70.xC8
Temporary fix
Comments
APAR Information
APAR number
IC97429
Reported component name
INFORMIX SERVER
Reported component ID
5725A3900
Reported release
B70
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2013-11-05
Closed date
2014-05-08
Last modified date
2024-09-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INFORMIX SERVER
Fixed component ID
5725A3900
Applicable component levels
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSGU8G","label":"Informix Servers"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B70","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
24 September 2024