Error description
Appliance might restart in the case of serializing big XML output where the output port temporarily cannot accept data.
Local fix
If the transaction output is generated by a final Results action, replace it by a Transform Binary action with the stylesheet below. If a Transform action sends a result directly to OUTPUT context, make it generate the result into a context (maybe PIPE) and add the above-mentioned Transform Binary action from the new context to OUTPUT. The following stylesheet is an example of a stylesheet used for the Tranform Binary action. This is the non-XML equivalent of store:///identity.xsl: <xsl:stylesheet version="1.0" xmlns:xsl="http://www.w3.org/1999/XSL/Transform" xmlns:dp="http://www.datapower.com/extensions" extension-element-prefixes="dp" > <dp:input-mapping href="store:///pkcs7-convert-input.ffd" type="ffd"/> <dp:output-mapping href="store:///pkcs7-convert-input.ffd" type="ffd"/> <xsl:template match="/"> <xsl:copy-of select="*"/> </xsl:template> </xsl:stylesheet>
Problem summary
DataPower might restart while serializing large XML output if the backend is unable to accept data.
Problem conclusion
Fix is available in 5.0.0.12, 6.0.0.4 and 6.0.1.0. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IC93036
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
382
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-06-12
Closed date
2013-10-03
Last modified date
2014-01-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
R100 PSN
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.8.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
11 February 2022