Error description
When the MQ Front Side Handler is connected to an alias Queue instead of a local input Queue, the MQ Backout Settings from the connected Queue Manager is not retrieved as expected. The result is that a failed Message remains in the local input Queue and is not transferred to the configured Backout Queue.
Local fix
The workaround is to use a local input Queue instead of an alias input Queue.
Problem summary
Customers who use Alias Queues and enable the "Retrieve Backout Settings" property in the MQ Front Side Handler are likely to see this problem. MQ Backout did not work correctly if MQ Front Side Handler connects and retrieves the backout setting from an Alias Queue.
Problem conclusion
The fix is available on 4.0.1.17, 4.0.2.13, and 5.0.0.8. For a list of the latest fix packs available, please see: http://www-01.ibm.com/support/docview.wss?uid=swg21237631
Temporary fix
Comments
APAR Information
APAR number
IC90364
Reported component name
DTPWR INTGRAPL
Reported component ID
DP905XI52
Reported release
500
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-02-21
Closed date
2013-04-25
Last modified date
2013-05-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DTPWR INTGRAPL
Fixed component ID
DP905XI52
Applicable component levels
R401 PSY
UP
R402 PSY
UP
R500 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSHT9H","label":"WebSphere DataPower Integration Appliance XI52"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
15 May 2013