APAR status
Closed as program error.
Error description
The Appliance Management Protocol (AMP) operation "SetDomainExport" will deploy a given export or backup package to a given domain name or list of services overwriting objects and files with the same names. With the Reset-Domain flag set to true, if the input content is invalid, the reset proceeds, returning the domain to its initial state regardless of success restoring the original configuration.
Local fix
Problem summary
AMP SetDomainExport operation with the Reset-Domain flag set to true, resets the target domain though the operation cannot be completed successfully because invalid input is supplied in the command. The domain configuration is reset and the original domain config is lost if the command fails. The domain reset operation must be performed after first verifying that all the input is valid.
Problem conclusion
The fix is available in 3.8.2.14, 4.0.1.12, 4.0.2.8 and 5.0.0.0
Temporary fix
Comments
APAR Information
APAR number
IC85247
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
500
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-07-11
Closed date
2012-07-18
Last modified date
2012-08-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R382 PSY
UP
R401 PSY
UP
R402 PSY
UP
R500 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.0.0","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]