Error description
When modifying a AAA Policy object that uses LTPA in the PostProcessing step, the undo feature may not work as expected. The change will be reverted, but the object will be down with an error about an invalid configuration.
Local fix
Reapply the object after running undo to bring the object back up.
Problem summary
Affected customers are those using a AAA policy configured with Generate LTPA Token in the PostProcessing step. The Undo function in the WebGUI causes the object to be marked down.
Problem conclusion
Undo now reverts the change and then the AAA object transitions back to op state up. The fix is available in 4.0.1.9 and 4.0.2.5.
Temporary fix
Comments
APAR Information
APAR number
IC81790
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
402
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-03-02
Closed date
2012-03-19
Last modified date
2012-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R401 PSY
UP
R402 PSY
UP
R500 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.0.2","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]