APAR status
Closed as program error.
Error description
After failover, on the new primary, insert statements get -239/-100 or -268/-100 because of a serial value.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of tables with SERIAL, SERIAL8, or BIGSERIAL columns * * on HDR, SDS, and RSS secondary servers. * **************************************************************** * PROBLEM DESCRIPTION: * * At a secondary server, the partition header saving the * * current value for a SERIAL, SERIAL8, or BIGSERIAL column is * * not updated correctly if the SERIAL, SERIAL8, or BIGSERIAL * * column reaches its maximum value and rolls over to 1. If * * this happens and the secondary server ever becomes a * * standard or primary server, attempts to insert into the * * table containing the SERIAL, SERIAL8, or BIGSERIAL column * * will result in duplicate values for the column(s). * **************************************************************** * RECOMMENDATION: * * Upgrade to IDS 11.50.xC10 or later. * ****************************************************************
Problem conclusion
Fixed in IDS 11.50.xC10.
Temporary fix
Comments
APAR Information
APAR number
IC79982
Reported component name
INFORMIX SERVER
Reported component ID
5725A3900
Reported release
B50
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2011-11-23
Closed date
2017-06-15
Last modified date
2017-06-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
INFORMIX SERVER
Fixed component ID
5725A3900
Applicable component levels
RB50 PSY
UP
RB70 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSGU8G","label":"Informix Servers"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B50","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
15 June 2017