Error description
When tabbing through or entering on a field with an EDTCDE(Y), the field loses the formatting. This problem only occurs when the host code page is set to 1388 (Simplified Chinese Extended). When using host code page 037 (US), the field retains formatting and works as expected.
Local fix
Manually modify JavaScript codes to disable the content checking for Numeric fields, so the slashes can be submitted to bring outr the screen.
Problem summary
**************************************************************** * USERS AFFECTED: DBCS users who render a numeric field with * * an EDTCDE(Y) to define the date format. * **************************************************************** * PROBLEM DESCRIPTION: Under DBCS code pages, when tabbing * * through or entering on a field with * * an EDTCDE(Y), the field loses the * * date formatting. * **************************************************************** * RECOMMENDATION: * **************************************************************** These date formattings are modified by DBCS content checking implementations
Problem conclusion
Under 1388 or other DBCS code pages, when users hit ENTER, HATS performs data type checking to ensure that only allowable data types can exist in the input fields. If illegal characters are found, HATS would remove illegal characters and do nothing to host application. The reason why HATS implements this for DBCS code pages but not SBCS code pages is that users might enter illegal characters through IME and our regular content checking cannot catch illegal characters until users hit ENTER to leave IME mode. In user's 1388 case, "From start date" is defined as a Numeric Only field, meaning forward slash is not a legal character to be submitted. After user submits 072811 to host, host application will convert 072811 to 7/28/11, which contains illegal characters forward slash, so HATS will perform content checking to remove slashes after user hits ENTER again. However, we determined that the case of using IME in numeric fields rarely exists, so the AutoIME content checking seems redundant and should be removed.
Temporary fix
Comments
APAR Information
APAR number
IC78098
Reported component name
RATL HATS FOR 5
Reported component ID
5724U6800
Reported release
750
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-08-14
Closed date
2012-02-29
Last modified date
2012-02-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL HATS FOR 5
Fixed component ID
5724U6800
Applicable component levels
R751 PSY
UP
R800 PSY
UP
Document Information
Modified date:
29 February 2012