APAR status
Closed as program error.
Error description
On XI50B and XI50z appliances, customers cannot change the configuration for the the enabled services on the XML management interface through the WebGUI. The check boxes for enabled services are being incorrectly disabled.
Local fix
Problem summary
DataPower customers changing enabled services on the xml management interface. The checkboxes to change the enabled services on the xml manager interface webGUI page are all disabled. The checkboxes are being disabled incorrectly.
Problem conclusion
The fix is available on 3.8.1.13, 3.8.1.14, 3.8.2.5, and 4.0.1.0
Temporary fix
Comments
APAR Information
APAR number
IC77470
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
381
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-07-12
Closed date
2011-07-14
Last modified date
2011-08-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R381 PSY
UP
R382 PSY
UP
R401 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.8.1","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]