Fixes are available
APAR status
Closed as program error.
Error description
Installed the latest PCOM 6.0.2.0 on a Win7 image. It seems like there is a change in the way PCOM reads the pcswin.ini file. We have [View1] Description=Startup defined in the pcswin.ini file. We use the "start-up.bch" file to launch the PCOM sessions. If [LastExitView] exists in the pcswin.ini, PCOM seems to ignore the defined "Startup" view and it also launches PCOM printer1.ws in the foreground. If [LastExitView] does NOT exist in the pcswin.ini, then PCOM sessions are opened as expected. This only happens in PCOM 6.0.2.0.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users * **************************************************************** * PROBLEM DESCRIPTION: Saved view does not work from BCH file * * or command line. * **************************************************************** * RECOMMENDATION: * **************************************************************** When a view is specified in command line or in a BCH file it is being overridden by the LastExitView function.
Problem conclusion
PCSWS.EXE has been changed to not run LastExitView when a saved view is used with a BCH file or command line to start emulator sessions. Fix scheduled for PCOM 5.9.8 Manufacturing Refresh Fix scheduled for PCOM 6.0.3 Manufacturing Refresh
Temporary fix
Comments
APAR Information
APAR number
IC74619
Reported component name
PCOMM V5 COMBO-
Reported component ID
5639I7000
Reported release
601
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-02-21
Closed date
2011-02-22
Last modified date
2012-05-09
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
PCSWS
Fix information
Fixed component name
PCOMM V5 COMBO-
Fixed component ID
5639I7000
Applicable component levels
R590 PSY IP23349
UP12/05/09 I 1000
R600 PSY
UP
R601 PSY
UP
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSEQ5Y","label":"Personal Communications"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0.1","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: