Error description
DataPower FFD feature does not convert zoned and Comp-3 numbers correctly.
Local fix
Problem summary
Affected are customers using Contivo Analyst as binary mapping tool with DataPower. The specified length attribute for fields of zoned or COMP-3 number type is not honored by DataPower.
Problem conclusion
Values will now be padded on the left with 0x00 for COMP-3 and 0xf0 for zoned numbers to fill up to the number of bytes specified by the field's length attribute. Fix is available in 3.8.0.7 and 3.8.1.5.
Temporary fix
Comments
APAR Information
APAR number
IC70238
Reported component name
DATAPOWER
Reported component ID
DP1234567
Reported release
380
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-07-27
Closed date
2010-09-20
Last modified date
2010-09-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DATAPOWER
Fixed component ID
DP1234567
Applicable component levels
R380 PSY
UP
R381 PSY
UP
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SS9H2Y","label":"IBM DataPower Gateway"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.8","Edition":"","Line of Business":{"code":"LOB45","label":"Automation"}}]