Error description
SYS-REQ key (Shift+Esc) does not work on Window7. only esc key could work and other shift+key are also no problem. stanza : DBCS USBkeyboard=106 in ini.file does not help.
Local fix
use WinXP
Problem summary
**************************************************************** * USERS AFFECTED: Some Japanese Windows 7 operating system * * users. * **************************************************************** * PROBLEM DESCRIPTION: Shift+Esc key mapping does not work on * * some hardware using PCOM 6.0 * **************************************************************** * RECOMMENDATION: * **************************************************************** Users with Windows 7 + PCOMM6.0 on ThinkCentre M90 Eco Ultra Small Type:3853-E1J cannot use Sysreq key by pressing Shift + Esc. The trace shows no keystroke entry. KMP maps Shift+Esc to ísys reqù. ESC key alone works fine on customer system. The problem only occurs on some specific machines. ThinkCentre M90 with A2/ Lenovo Preferred Pro USB Fingerprint keyboard in this case. With user's specific hardware, when Shift and Esc key are pressed at the same time, the original function to detect the Shift key status returns KeyUp instead of KeyDown, so PCOMM will mis-convert the key function.
Problem conclusion
PCSKBD.DLL has been changed to do additional key status detect checking before converting the Shift key function. Fix is scheduled for PCOM 5.9.7 Manufacturing Refresh Fix is scheduled for PCOM 6.0.1.1 Refresh Pack
Temporary fix
Comments
APAR Information
APAR number
IC69939
Reported component name
PCOMM V5 COMBO-
Reported component ID
5639I700J
Reported release
600
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-07-15
Closed date
2010-07-19
Last modified date
2010-08-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
PCSKDB
Fix information
Fixed component name
PCOMM V5 COMBO-
Fixed component ID
5639I700J
Applicable component levels
R590 PSY IP23149
UP10/08/18 I 1000
R600 PSY
UP