Fixes are available
APAR status
Closed as program error.
Error description
The users receive the PCSWS.EXE error (Faulting application pcsws.exe, version 5090.5.9162.553, faulting module msvcrt.dll, version 7.0.2600.5512, fault address 0x00037410.) when they try to copy and paste in the Telnet 5250 sessions. They use the PCOM menu to copy and paste. These sites are still using XP and running PCOM 5.9.2.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All users doing paste operation to a PCOMM * * emulator session window. * **************************************************************** * PROBLEM DESCRIPTION: Access violation in pcsws doing paste * * operation to a PCOMM screen using Edit * * menu option. * **************************************************************** * RECOMMENDATION: * **************************************************************** The problem is due to access of memory beyond the buffer boundary during paste operation from clipboard.
Problem conclusion
PCSEDIT.DLL has been changed to access memory properly using a boundary check so that we do not go beyond the limit of the memory buffer. Fix scheduled for PCOM 5.9.7 Manufacturing Refresh Fix scheduled for PCOM 6.0.2 Manufacturing Refresh
Temporary fix
Comments
APAR Information
APAR number
IC69213
Reported component name
PCOMM V5 COMBO-
Reported component ID
5639I7000
Reported release
590
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-06-15
Closed date
2010-06-22
Last modified date
2010-09-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
PCSEDIT
Fix information
Fixed component name
PCOMM V5 COMBO-
Fixed component ID
5639I7000
Applicable component levels
R590 PSY IP23148
UP10/09/02 I 1000
R600 PSY
UP