APAR status
Closed as program error.
Error description
project settings using Screen size 27x132 but the screen is bein g rendered using 24x80.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: User with screen size configured to 27 X 132 * * * **************************************************************** * PROBLEM DESCRIPTION: Data (Characters) not getting * * displayed completely on the display * * screen. * **************************************************************** * RECOMMENDATION: * * * **************************************************************** When host sends a Clear Unit Alternate, with the parameter value set to 0x00, the screen size is suppose to change to 27 x 132. Sometimes, though, the screen size value will remain as 24 X 80. When the screen is the wrong size there are times when invalid row/column calculations are made causing a negative response of 0x10050122 to be sent back to the host. The host then terminates the session.
Problem conclusion
Clear Unit Alternate" command processing code was modified to fix this issue. Fix will be delivered in the following HATS releases: HATS 6.0.10 HATS 7.0.0.5 HATS 7.1.0.4 HATS 7.5.0.1
Temporary fix
Comments
APAR Information
APAR number
IC59452
Reported component name
HATS MULTI
Reported component ID
5724L0200
Reported release
600
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-01-13
Closed date
2009-06-01
Last modified date
2009-06-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
HATS MULTI
Fixed component ID
5724L0200
Applicable component levels
R600 PSY
UP
R700 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXKAY-2","label":"Rational Host Access Transformation Services"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.0","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]