IBM Support

HE12667: ICC CONSTRUCTOR FAILS TO CONNECT TO P8 REPOSITORY WHEN USING A CUSTOM PATH.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • While creating P8 connection in ICC, the path is always taken
    as wsi/FNCEWS40MTOM, even if configuration uses a different
    path such as wsiedm/FNCEWS40MTOM.
    

Local fix

  • Manually modify IBM\Content Search Services\CSS
    Server\config\afu_config_Email.cache to use the custom path.
    The cache file is in the same directory as constructor.xml.
    

Problem summary

  • While creating P8 connection in ICC, the path is always taken
    as wsi/FNCEWS40MTOM, even if configuration uses a different
    path such as wsiedm/FNCEWS40MTOM.
    

Problem conclusion

  • Starting with IBM Content Collector 4.0.1 FP5 release, this
    issue has been fixed. While creating P8 connection, ICC will now
     use the custom path set on the configuration UI.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE12667

  • Reported component name

    ICC FOR EMAIL

  • Reported component ID

    5724V5700

  • Reported release

    401

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-05-05

  • Closed date

    2017-06-07

  • Last modified date

    2017-06-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ICC FOR EMAIL

  • Fixed component ID

    5724V5700

Applicable component levels

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAE9L","label":"Content Collector"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"4.0.1","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
31 August 2023