APAR status
Closed as program error.
Error description
Abstract: Measure Inertia bounding box values is Wrong by factor of 1k (1000) when multiple bodies are selected. Scenario: 0. Start CATIA V5R21 1. Create a new part 2. Activate the PartBody 3. Create a closed box sketch 4. Create a Pad from the sketch 5. Create another Body (Activate this Body) 6. Create a closed box sketch 7. Create a Pad from the sketch 8. Create a 3D Inertia measurement ? Select the PartBody and then hold control and select the other Body. (The measurement now contains both inputs) 9. Click the f(x) and select the InertiaVolume at the bottom of the spec tree. 10. There are 6 attributes which are incorrect BBOx, BBOy, BBOz, BBLx, BBLy, BBLz and if you multiple these values by 1000, they are correct. BBO represents the Bounding Box Origin point and BBL represents the lengths of the box from the origin point along the inertia axes. Result: There are 6 attributes which are incorrect BBOx, BBOy, BBOz, BBLx, BBLy, BBLz. Expected result: Measure Inertia bounding box values should be correct by factor when multiple bodies are selected.
Local fix
empty
Problem summary
Abstract: Measure Inertia bounding box values is Wrong by factor of 1k (1000) when multiple bodies are selected. Scenario: 0. Start CATIA V5R21 1. Create a new part 2. Activate the PartBody 3. Create a closed box sketch 4. Create a Pad from the sketch 5. Create another Body (Activate this Body) 6. Create a closed box sketch 7. Create a Pad from the sketch 8. Create a 3D Inertia measurement ??? Select the PartBody and then hold control and select the other Body. (The measurement now contains both inputs) 9. Click the f(x) and select the InertiaVolume at the bottom of the spec tree. 10. There are 6 attributes which are incorrect BBOx, BBOy, BBOz, BBLx, BBLy, BBLz and if you multiple these values by 1000, they are correct. BBO represents the Bounding Box Origin point and BBL represents the lengths of the box from the origin point along the inertia axes. Result: There are 6 attributes which are incorrect BBOx, BBOy, BBOz, BBLx, BBLy, BBLz. Expected result: Measure Inertia bounding box values should be correct by factor when multiple bodies are selected.
Problem conclusion
THIS PROBLEM WILL BE FIXED ON I-PLM Collaborative Innovation VERSION V5-6R2012 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP7. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R21 SP2. Additional Closure Information: Incident Diagnosis: Measure Inertia bounding box values KO by factor of 1k when multiple bodies are selected Reason: Actually the there was a problem in the bounding box computation of measure and which has been corrected now.However, the problem is fixed when a new measure created. Important Note: There was a problem in the bounding box computation which has been corrected now(V5R21SP2 level), but this will be effective only for measures created with the new algorithm. i.e., the measure which were already created will use the old algorithm will not update, because of the version saved in side the measure feature. so new algorithm will only called for the newly created measures.
Temporary fix
Comments
APAR Information
APAR number
HE08136
Reported component name
CATIA V5 WIN 64
Reported component ID
569165000
Reported release
521
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-06-22
Closed date
2011-11-21
Last modified date
2011-11-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 WIN 64
Fixed component ID
569165000
Applicable component levels
R520 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"521","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date: