APAR status
Closed as program error.
Error description
SCENARIO: 1) Start CATIA. 2) Open the file CATAnalysis file. (Workbench : "Generative Structural Analysis". ) 3) Click Translational displacement magnitude in the tree, and Select "Activate/Deactivate" from context menu. The "Warning" window is displayed. The Solution needs to be updated. This operation may take some time ! Continue ? 4) Click "OK" in the "Warning" Window. >> Computation is executed. 5) Expand the tree. 6) Double click any part in the tree. Workbench is changed into "Part Design". 7) Deactivate any featue linked with the connection property. 8) Double click Links Manager in the tree. 9) Click Translational displacement magnitude in the tree, and Select "Activate/Deactivate" from context menu. 10) Click "OK" in the "Warning" Window. Computation is executed. Problem: The error message is not displayed even if it loses the element which the "General Analysis Connection" set. Expected Result: The error message should be displayed in the case which lost the element which the "General Analysis Connection" set. And execution of computation should be stopped.
Local fix
empty
Problem summary
SCENARIO: 1) Start CATIA. 2) Open the file CATAnalysis file. (Workbench : "Generative Structural Analysis". ) 3) Click Translational displacement magnitude in the tree, and Select "Activate/Deactivate" from context menu. The "Warning" window is displayed. The Solution needs to be updated. This operation may take some time ! Continue ? 4) Click "OK" in the "Warning" Window. >> Computation is executed. 5) Expand the tree. 6) Double click any part in the tree. Workbench is changed into "Part Design". 7) Deactivate any featue linked with the connection property. 8) Double click Links Manager in the tree. 9) Click Translational displacement magnitude in the tree, and Select "Activate/Deactivate" from context menu. 10) Click "OK" in the "Warning" Window. Computation is executed. Problem: The error message is not displayed even if it loses the element which the "General Analysis Connection" set. Expected Result: The error message should be displayed in the case which lost the element which the "General Analysis Connection" set. And execution of computation should be stopped.
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION V5R21 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP5. Additional Closure Information: Incident Diagnosis: The error message is not displayed even if it loses the element which the "General Analysis Connection" set. Technical explanation of the defect: Error message was not raised when no elements/nodes were not associated to the first support only. The second support overloaded the first failing return code and didn't raise the first error. Technical explanation of the correction: The algorithm has been improved to break the supports loop and raise an error on any support. Possible by-pass and/or correction limitation: No by-pass/limitation with the correction. Just re mesh the connection mesh part. Code is corrected and problem will not be reproduced on V5R20SP05 and V5R21GA
Temporary fix
Comments
APAR Information
APAR number
HE02897
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-12-20
Closed date
2011-01-06
Last modified date
2011-01-06
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R520 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
06 January 2011