APAR status
Closed as program error.
Error description
Scenario: . Toolpath should is not computed with forced computation after opening CATProcess in CATIA without modification inside the Machining operation. : Message is obtained that ???Nothing to Mill??? . Expected Result: Toolpath should be computed with forced computation after opening CATProcess in CATIA without modification inside the Machining operation. .
Local fix
empty
Problem summary
Scenario: . Toolpath should is not computed with forced computation after opening CATProcess in CATIA without modification inside the Machining operation. : Message is obtained that ???Nothing to Mill??? . Expected Result: Toolpath should be computed with forced computation after opening CATProcess in CATIA without modification inside the Machining operation. .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION V5R21 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP5. Additional Closure Information: Incident Doagonosis . Machining (AMG) / Warning message ???Nothing to Mill??? is obtained while toolpath computation . Correction Explanation . When "MFG_PART_FROM_PO" is enabled, the negative value of offset on contour was not handled correctly. The computation is not possible for large negative thickness. Hence, now a error message would be popped up saying "Too large negative thickness on geometry" when the value is given too less than 0. Also, the design parts selected in Part Operation are more than required. In the PMR data, there are 4 Design parts selected and of these, the third and fourth are the same parts. These huge inputs results in erroneous tool path. Please remove all the selected Design parts and select only the first part "/HAM2760102106_A-3/alteVersion_alsRT/alteVersion_alsRT/Comple te Machined Crankcase ". This is the only necessary part. With this part selected and offset on contour value given as -9.8 mm, the computation of toolpath is completed correctly . Note : In 32 bit system the problem occurs sometimes.In 64 bits its OK. .
Temporary fix
Comments
APAR Information
APAR number
HE01969
Reported component name
CATIA V5 WIN 64
Reported component ID
569165000
Reported release
519
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-11-19
Closed date
2010-12-16
Last modified date
2010-12-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 WIN 64
Fixed component ID
569165000
Applicable component levels
R520 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
16 December 2010