  • Scenario:
    1. Open the CATProduct file in CATIA: ASD workbench.
    2. Click on Analyze>Bill of Material.
    3. Click on ???Define Formats??? in the BOM tab.
    4. On the bottom list of "Properties for the Recapitulation"
    click on "<" and add one by one all attributes
         except ???number???. Now click OK.
    5.  Go to ???Define formats??? again and now try to transfer the
    
    ???number??? attribute and click OK  ,
          then observe.
    Problem:
    Catia hangs unexpectedly.
    Expected Result:
    CATIA should not hang and the number attribute should be
    transferred accordingly.
    

Local fix

  • empty
    

Problem summary

  • Scenario:
    1. Open the CATProduct file in CATIA: ASD workbench.
    2. Click on Analyze>Bill of Material.
    3. Click on ???Define Formats??? in the BOM tab.
    4. On the bottom list of "Properties for the Recapitulation"
    click on "<" and add one by one all attributes
         except ???number???. Now click OK.
    5.  Go to ???Define formats??? again and now try to transfer the
    
    ???number??? attribute and click OK  ,
          then observe.
    Problem:
    Catia hangs unexpectedly.
    Expected Result:
    CATIA should not hang and the number attribute should be
    transferred accordingly.
    

Problem conclusion

  • NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP5.
    Additional Closure Information:
    Technical explanation of the defect:
    'Number' attribute in Bill of Materials makes
    CATIA hang
    Technical explanation of the correction:
    Conditional break.
    Possible by-pass and/or correction limitation:
    none
    

Temporary fix

Comments

APAR Information

  • APAR number

    HE00489

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    519

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-09-29

  • Closed date

    2010-11-22

  • Last modified date

    2010-11-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R520 PSN

       UP