APAR status
Closed as Permanent restriction.
Error description
Scenario: 1) Start 64-bit CATIA V5R19SP3 on Windows 64bit 2) Open the CATDrawing -> It is not possible to open the drawing -> The following error message appears: . Problem while reading document. Load operation failed Invalid data. No editor associated . 3) Start CATIA V5R19SP3 on Windows 32bit 4) Open the CATDrawing -> It is possible to load the CATDrawing -> The following error message appaers: . Standards have not been loaded for document?? because of data inconsistency . **************************************************************** ************************************* DS ONLY Problem reproduced using 64-bit CATIA R21 under windows 64-bit. After Open and Save using 32-bit CATIA R21 under windows 32-bit, the resulting drawing can be opened using 64-bit CATIA R21 under windows 64-bit. . ABK
Local fix
empty
Problem summary
Scenario: 1) Start 64-bit CATIA V5R19SP3 on Windows 64bit 2) Open the CATDrawing -> It is not possible to open the drawing -> The following error message appears: . Problem while reading document. Load operation failed Invalid data. No editor associated . 3) Start CATIA V5R19SP3 on Windows 32bit 4) Open the CATDrawing -> It is possible to load the CATDrawing -> The following error message appaers: . Standards have not been loaded for document?? because of data inconsistency . ************************************************************** *************************************** DS ONLY Problem reproduced using 64-bit CATIA R21 under windows 64-bit. After Open and Save using 32-bit CATIA R21 under windows 32-bit, the resulting drawing can be opened using 64-bit CATIA R21 under windows 64-bit. . ABK
Problem conclusion
Incident Diagnosis: Analysis shows that the problem is caused by the CEG1 drafting standard in the drawing. The development team have replaced the invalid standard with the ISO standard and the corrected drawing is available. Note: Further investigation will be made if the customer can providde the CEG1.xml file and the scenario that results in the problematic drawing. . THIS PROBLEM IS A PERMANENT RESTRICTION
Temporary fix
Comments
APAR Information
APAR number
HE00067
Reported component name
CATIA V5 WIN 64
Reported component ID
569165000
Reported release
519
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-09-14
Closed date
2012-04-24
Last modified date
2012-04-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
24 April 2012