APAR status
Closed as program error.
Error description
CATIA V5 - SmarTeam integration issue. . Prerequisites: In CATIA: tools / options / equipment and systems / Design Criteria / 3D Design : Schematic Driven is checked tools / options / General / Document / Document Environment : SmarTeam is current . Scenario 1/ Start CATIA V5. Connect to SmarTeam 2/ Go to equipment /piping / piping and instrumentation diagrams 3/ click on OK for the document creation 4/ route a piping line 5/ place a component like a pump 6/ save to smarteam the product 7/ Close CATIA 8/ Restart CATIA and connect to SmarTeam 6/ go to equipment / piping / piping design 7/ route a run ==> the SchematicBrowser window opens 8/ click on the browse icon (open schematic diagram) 9/ search in SmarTeam the targeted Product 10/ select it and click on OK ==> In CATIA, it is not inserted. 11/ Repeat steps 8 and 9 ==> It is now inserted properly Expected behavior : It should work at the first try, not at the second try.
Local fix
empty
Problem summary
CATIA V5 - SmarTeam integration issue. . Prerequisites: In CATIA: tools / options / equipment and systems / Design Criteria / 3D Design : Schematic Driven is checked tools / options / General / Document / Document Environment : SmarTeam is current . Scenario 1/ Start CATIA V5. Connect to SmarTeam 2/ Go to equipment /piping / piping and instrumentation diagrams 3/ click on OK for the document creation 4/ route a piping line 5/ place a component like a pump 6/ save to smarteam the product 7/ Close CATIA 8/ Restart CATIA and connect to SmarTeam 6/ go to equipment / piping / piping design 7/ route a run ==> the SchematicBrowser window opens 8/ click on the browse icon (open schematic diagram) 9/ search in SmarTeam the targeted Product 10/ select it and click on OK ==> In CATIA, it is not inserted. 11/ Repeat steps 8 and 9 ==> It is now inserted properly Expected behavior : It should work at the first try, not at the second try.
Problem conclusion
THIS PROBLEM WILL BE FIXED ON CATIA VERSION 5 RELEASE 21 GA level. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON CATIA V5R20SP3. Additional Closure Information: .
Temporary fix
Comments
APAR Information
APAR number
HD96174
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
519
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-05-10
Closed date
2010-06-21
Last modified date
2010-08-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R520 PSN SP52003
UP10/08/20 I 1000
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
20 August 2010