Error description

  • VPMV5NAV:FREE NAMING,IF PART NUMBER IS CHANGED IN CATIA,
    PARTVERSION::PART NUMBER(V_ID)WILL BE REPLACE
    Preparation:
    
    Prep1  Activate free naming from
    tools-->options-->Compatibility-->ENOVIA VPM V5--> set part
    and document identifier attribute as V_name
    
    Prep2  Create Test.CATProduct and save to VPM NAVIGATOR
    .
    Scenario:
    
     1 Logon to VPMNAVI and search the PROD Test.CATProduct
    
     2 Open the Test.CATProduct  by  Document Window.
    
     3 Change the Part Number to "newtest" from Properties panel.
    
     4 Save it to VPMNAVI.
    Actual result:Search part vesion Test.CATProduct.The
    V_ID(part number) of the part version is changed to "newtest"
    Expected result:Free naming activated hence only V_name of
    the part vesion should be changes and V_ID(part number)
    should remain unchanged.
    

Local fix

  • empty
    

Problem summary

  • VPMV5NAV:FREE NAMING,IF PART NUMBER IS CHANGED IN CATIA,
    PARTVERSION::PART NUMBER(V_ID)WILL BE REPLACE
    Preparation:
    
    Prep1  Activate free naming from
    tools-->options-->Compatibility-->ENOVIA VPM V5--> set part
    and document identifier attribute as V_name
    
    Prep2  Create Test.CATProduct and save to VPM NAVIGATOR
    .
    Scenario:
    
     1 Logon to VPMNAVI and search the PROD Test.CATProduct
    
     2 Open the Test.CATProduct  by  Document Window.
    
     3 Change the Part Number to "newtest" from Properties panel.
    
     4 Save it to VPMNAVI.
    Actual result:Search part vesion Test.CATProduct.The
    V_ID(part number) of the part version is changed to "newtest"
    Expected result:Free naming activated hence only V_name of
    the part vesion should be changes and V_ID(part number)
    should remain unchanged.
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON ENOVIA VERSION V5R21 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP3.
    Additional Closure Information:
    Free naming activated hence only V_name of the part vesion
    will be changes and V_ID(part number) will remain unchanged.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD96066

  • Reported component name

    ENOVIA V5 VPM N

  • Reported component ID

    569151400

  • Reported release

    519

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-05-06

  • Closed date

    2010-06-08

  • Last modified date

    2010-08-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ENOVIA V5 VPM N

  • Fixed component ID

    569151400

Applicable component levels

  • R520 PSN SP52003

       UP10/08/20 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS7P2G","label":"ENOVIA V5 VPM Discipline"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
20 August 2010