APAR status
Closed as program error.
Error description
Scenario (tested in SmDemo): - Integration tools setup, mapped custom attributes, configuration Specific: SolidWorks Part - Part Number - Option Simplified configuration extension: SM* - Create SolidWorks part, configuration name = Default - Add derived configuration, configuration name = DefaultSMtest - Remove all custom properties from configuration (top-level + derived) - Save part in SmarTeam. Fill all fields on the SmarTeam profile card - Custom properties of top-level configuration are copied from SmarTeam. Custom properties of derived configuration are empty Remark: Option Save derived configurations has no influence on the result. This is an important defect, because the customer uses drawing views that reference the derived configuration instead of the default configuration. But the tileblock uses the same configuration as the drawing view, so the titleblock attributes are empty. Workaround: Create an invisible drawing view that references the default configuration, and link the titleblock to that view. Current Result:-Mapped custom properties in a SolidWorks derived configuration are not updated, if the configuration is a simple configuration. This is a regression since ST V5R16 + SW 2006.
Local fix
empty
Problem summary
Scenario (tested in SmDemo): - Integration tools setup, mapped custom attributes, configuration Specific: SolidWorks Part - Part Number - Option Simplified configuration extension: SM* - Create SolidWorks part, configuration name = Default - Add derived configuration, configuration name = DefaultSMtest - Remove all custom properties from configuration (top-level + derived) - Save part in SmarTeam. Fill all fields on the SmarTeam profile card - Custom properties of top-level configuration are copied from SmarTeam. Custom properties of derived configuration are empty Remark: Option Save derived configurations has no influence on the result. This is an important defect, because the customer uses drawing views that reference the derived configuration instead of the default configuration. But the tileblock uses the same configuration as the drawing view, so the titleblock attributes are empty. Workaround: Create an invisible drawing view that references the default configuration, and link the titleblock to that view. Current Result:-Mapped custom properties in a SolidWorks derived configuration are not updated, if the configuration is a simple configuration. This is a regression since ST V5R16 + SW 2006.
Problem conclusion
NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R19 SP7. Additional Closure Information: fixed
Temporary fix
Comments
APAR Information
APAR number
HD92439
Reported component name
SMARTEAM NT>XP
Reported component ID
569199970
Reported release
519
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2010-01-06
Closed date
2010-03-05
Last modified date
2010-03-05
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SMARTEAM NT>XP
Fixed component ID
569199970
Applicable component levels
R519 PSN
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS2S3T","label":"ENOVIA SmarTeam V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
05 March 2010