Error description
Scenario: 1. Launch the Tubing workbench of CATIA V5 R19 SP3 2. Click on Route a Run - The run command displays the Turn Rules depending upon the current line ID value. 3. Select the appropriate row in the table Result: When the user picks up one of the rows in the Turn rules table, the bending rules tables will be searched for the corresponding Minimum Tangent Length. Concern: As per current implementation the code picks up the first match from the bending rule table. Expected Result: A list of matching rows from the bending rule table should be displayed so that the user can pick the suitable result.
Local fix
empty
Problem summary
Scenario: 1. Launch the Tubing workbench of CATIA V5 R19 SP3 2. Click on Route a Run - The run command displays the Turn Rules depending upon the current line ID value. 3. Select the appropriate row in the table Result: When the user picks up one of the rows in the Turn rules table, the bending rules tables will be searched for the corresponding Minimum Tangent Length. Concern: As per current implementation the code picks up the first match from the bending rule table. Expected Result: A list of matching rows from the bending rule table should be displayed so that the user can pick the suitable result.
Problem conclusion
NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R19 SP7. NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R20 SP2. Additional Closure Information: Technical explanation of the defect: When the user picks up one of the rows in the Turn rules dialog during run routing, the bending rules table will be searched for selected Nominal Size and Bend Radius combination and the corresponding Minimum Tangent Length is registered for further run routing. As per current implementation the code picks up the first match from the bending rule table. Hence user is not able to set different MinTangent Length even if entries are made in Bending rule text file. Technical explanation of the correction: With this enhancement, the bending rule panel is displayed to the user if there are multiple entries in Bending rule text file for selected combination of Nominal Size and Bend radius. The user can interactively select a row from the panel to set the min tangent length. Note: This enhancement is delivered under a flag. The user needs to set this environment flag equal to 1 in order to display the bending rule table.
Temporary fix
Comments
APAR Information
APAR number
HD91214
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
519
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-11-27
Closed date
2010-02-15
Last modified date
2010-02-15
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5 NT>XP
Fixed component ID
569151000
Applicable component levels
R519 PSN
UP