APAR status
Closed as documentation error.
Error description
Need to update the documentation regarding 3 Orbix configuration. . This is inrelation with DETAILED DESCRIPTION: To activate Single sign on three different orbix configurations are made, all according to the online documentation, (Installation & Deployment->Deploying ENOVIA Applications- >Deploying Webtop and Wintop Applications->Deploying the Web Application in an Application Server->Configuring Single Sign-On->Activating Single Sign-On.): . Orbix: for batchusers (not SSO) Port: 16000 Orbix2: SSO for Webtop (LCA Nav) Port: 16300 Orbix3: SSO for Wintop (VPM Nav) Port: 16600 . When a user is logging on to VPMNav and tries to access the vault a process for the third orbix process is automatically starting up That results in problems to save files in the Enovia vault. User got this error message when trying to save a product into the Enovia vault: Error An error occured during save sequence. Save aborted. Warning Cannot update document's data in ENOVIA V5 VPM Server. . Customer Implementation: 1. One vault defined on the orbix port 16000. The VaultClient.properties file is configured to port 16000 2. One orbix port, 16300, defined for SSO in Wintop applications i.e. VPMNav and LCA classic 3. One orbix port, 16600, defined for SSO in Webtop applications i.e. LCANav . Customer Problem: When you tries to save automatically aniother Vault Process getting started. . OJH has anlayse this Issue and found that it is limitation on AIX.So As per OJH following restriction should be updated in the documentation. Here is the limitation description : . Operating System: AIX. The Orbix connection from an ENOVIA App Server launched by an Orbix Daemon A to a Vault Server fails if the Vault Server is running on the same machine and has not been launched by the same Orbix Daemon A. . By-pass: It is recommended to deploy the Vault Server on a dedicated machine which is not shared with the ENOVIA App Servers. If it is not possible to have a dedicated machine, then the same Orbix daemon has to be used for ENOVIA App Server and the Vault Server
Local fix
Problem summary
Need to update the documentation regarding 3 Orbix configuration. . This is inrelation with DETAILED DESCRIPTION: To activate Single sign on three different orbix configurations are made, all according to the online documentation, (Installation & Deployment->Deploying ENOVIA Applications- >Deploying Webtop and Wintop Applications->Deploying the Web Application in an Application Server->Configuring Single Sign-On->Activating Single Sign-On.): . Orbix: for batchusers (not SSO) Port: 16000 Orbix2: SSO for Webtop (LCA Nav) Port: 16300 Orbix3: SSO for Wintop (VPM Nav) Port: 16600 . When a user is logging on to VPMNav and tries to access the vault a process for the third orbix process is automatically starting up That results in problems to save files in the Enovia vault. User got this error message when trying to save a product into the Enovia vault: Error An error occured during save sequence. Save aborted. Warning Cannot update document's data in ENOVIA V5 VPM Server. . Customer Implementation: 1. One vault defined on the orbix port 16000. The VaultClient.properties file is configured to port 16000 2. One orbix port, 16300, defined for SSO in Wintop applications i.e. VPMNav and LCA classic 3. One orbix port, 16600, defined for SSO in Webtop applications i.e. LCANav . Customer Problem: When you tries to save automatically aniother Vault Process getting started. . OJH has anlayse this Issue and found that it is limitation on AIX.So As per OJH following restriction should be updated in the documentation. Here is the limitation description : . Operating System: AIX. The Orbix connection from an ENOVIA App Server launched by an Orbix Daemon A to a Vault Server fails if the Vault Server is running on the same machine and has not been launched by the same Orbix Daemon A. . By-pass: It is recommended to deploy the Vault Server on a dedicated machine which is not shared with the ENOVIA App Servers. If it is not possible to have a dedicated machine, then the same Orbix daemon has to be used for ENOVIA App Server and the Vault Server
Problem conclusion
THIS MODIFICATION WILL BE INCLUDED IN THE DOCUMENTATION DELIVERED WITH I-PLM Collaborative Innovation VERSION V5R20 Additional Closure Information: THIS MODIFICATION WILL BE INCLUDED IN THE DOCUMENTATION DELIVERED WITH ENOVIA VERSION 5 RELEASE 20 GA LEVEL. Additional Closure Information: Documentation Reference: . Installation and Deployment Guide; Getting Started Setting Up Vault Servers and Clients Installing the Vault Server Manually . Following Note has been documented Now; Note about Orbix On AIX ----------------------------- The Orbix connection from an ENOVIA App Server launched by an Orbix Daemon A to a Vault Server fails if the Vault Server is running on the same machine and has not been launched by the same Orbix Daemon A.The recommended by-pass is to deploy the VaultServer on a dedicated machine which is not sharedwith the ENOVIA App Servers. If it is not possibleto have a dedicated machine, then the same Orbix daemon has to be used for ENOVIA App Serverand the Vault Server.It has also been added to the chapter"ActivatingSingle Sign-On", section "Enabling Wintop andWebtop Applications to Share the Same ENOVIA V5 Server".
Temporary fix
Comments
APAR Information
APAR number
HD83832
Reported component name
ENOVIA LCA AIX
Reported component ID
569101700
Reported release
519
Status
CLOSED DOC
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2009-04-02
Closed date
2010-01-21
Last modified date
2010-01-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSDJRN","label":"ENOVIA LCA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
21 January 2010