HD80114: VPMV5NAV: ENOVIA V5 VPM V5R19 NEW FUNCTION PREVIEW: THE INSTANC E POSITION IS WRONG.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • VPMV5NAV: ENOVIA V5 VPM V5R19 NEW
    FUNCTION PREVIEW: THE INSTANCE POSITION IS
    WRONG.
    .
    SCENARIO:
    Preparation ? Start File Introspection.
    .
    Scenario ?
    1. Create PRC, sub-assembly and two CATParts
    under it.
    2. Start File Introspection.
    3. Open the PRC and expand.
    4. Select parts and it's property menu.
    5. Check preview tab. Check position, no problem.
    6. Open the PRC and loaded all parts into CATIA
    design window.
    7. Move the position between instances and save
    back into ENOVIA.
    8. Close CATIA design window and VPM Navigator
    window.
    9. Re-Open the PRC and expand.
    10. Select parts and open property.
    11. Check preview tab again.
    .
    Problem ? Position in preview is wrong.
    .
    Expected Result: Correct position should be shown
    in preview.
    .
    .
    

Local fix

Problem summary

  • VPMV5NAV: ENOVIA V5 VPM V5R19 NEW FUNCTION PREVIEW: THE INSTANC
    E POSITION IS WRONG.
    VPMV5NAV: ENOVIA V5 VPM V5R19 NEW
    FUNCTION PREVIEW: THE INSTANCE POSITION IS
    WRONG.
    .
    SCENARIO:
    Preparation ? Start File Introspection.
    .
    Scenario ?
    1. Create PRC, sub-assembly and two CATParts
    under it.
    2. Start File Introspection.
    3. Open the PRC and expand.
    4. Select parts and it's property menu.
    5. Check preview tab. Check position, no problem.
    6. Open the PRC and loaded all parts into CATIA
    design window.
    7. Move the position between instances and save
    back into ENOVIA.
    8. Close CATIA design window and VPM Navigator
    window.
    9. Re-Open the PRC and expand.
    10. Select parts and open property.
    11. Check preview tab again.
    .
    Problem ? Position in preview is wrong.
    .
    Expected Result: Correct position should be shown
    in preview.
    .
    .
    

Problem conclusion

Temporary fix

Comments

  • THE PROBLEM WAS SUBMITTED ON ENOVIA
    VERSION 5 RELEASE 19.
    THIS PROBLEM IS NOT REPRODUCIBLE ON ENOVIA
    VERSION 5 RELEASE 20 GA LEVEL. PLEASE NOTE
    THAT THIS ISSUE IS ALSO NOT REPRODUCIBLE
    ON V5R19SP03 LEVEL.
    .
    

APAR Information

  • APAR number

    HD80114

  • Reported component name

    ENOVIA V5 VPM A

  • Reported component ID

    569101400

  • Reported release

    519

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-11-26

  • Closed date

    2008-11-27

  • Last modified date

    2009-01-22

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    ENOVIA V5 VPM A

  • Fixed component ID

    569101400

Applicable component levels

  • R519 PSN SP51903

       UP09/01/22 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SS7P2G","label":"ENOVIA V5 VPM Discipline"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"519","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
22 January 2009