IBM Support

HD79380: DRAFTING (INTDRAFT) /CONTROL POINTS OF THE SPLINE IS STILL IN N OSHOW AFTER SHOWING THE SPLINE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • Drafting (IntDraft) /Control Points of the spline is
    still in NoShow after showing the spline
    .
    SCENARIO:
    .
    1. Open CATIA V5.
    2. Open CATDrawing.
    3. Select the spline by trap.
    4. Click on the "Hide/Show" icon.
    5. Click on the "Swap Visible Space" icon.
    6. Click on the Spline to select it.
    7. Click on the "Hide/Show" icon.
    8. Click on the "Swap Visible Space" icon.
    .
    RESULTS OBTAINED:
    .
    Control points are still in the NoShow space and
    only spline without control point displays in sheet.
    .
    EXPECTED RESULT:
    .
    The control points should be in show space by this
    operation.
    .
    .
    

Local fix

Problem summary

  • Drafting (IntDraft) /Control Points of the spline is still in N
    oShow after showing the spline
    Drafting (IntDraft) /Control Points of the spline is
    still in NoShow after showing the spline
    .
    SCENARIO:
    .
    1. Open CATIA V5.
    2. Open CATDrawing.
    3. Select the spline by trap.
    4. Click on the "Hide/Show" icon.
    5. Click on the "Swap Visible Space" icon.
    6. Click on the Spline to select it.
    7. Click on the "Hide/Show" icon.
    8. Click on the "Swap Visible Space" icon.
    .
    RESULTS OBTAINED:
    .
    Control points are still in the NoShow space and
    only spline without control point displays in sheet.
    .
    EXPECTED RESULT:
    .
    The control points should be in show space by this
    operation.
    .
    .
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN
    CATIA
    INCIDENT DIAGNOSIS:
    .
    Drafting (IntDraft) /Control Points of the spline is
    still in NoShow after showing the spline.
    .
    RESTRICTION EXPLANATION:
    .
    The control points are under the spline. Thus they
    cannot be visualized in the visible space if the
    spline is not shown. That is why when hiding only
    the spline, the control points are hidden too.
    However, you can visualize the spline without its
    control points, by hiding every single control points
    explicitly.
    .
    When selecting the spline by the trap, the user
    actually selects 9 elements (as indicated in the
    status bar "9 elements selected"): the spline and its
    8 control points. When clicking Hide, he explicitly
    hides the spline and every single control point.
    After swapping visible space, selecting the spline
    only and clicking Show only asks for showing back
    the spline. As the control points have been
    previously hidden, they remain so. This is the
    standard behaviour in Part Design, Sketcher and
    drafting.
    .
    BY-PASS:
    .
    As the user wants to hide the spline + every single
    point with the trap, he must select everything again
    with the trap and click show.
    .
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD79380

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    518

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-11-05

  • Closed date

    2009-02-12

  • Last modified date

    2009-02-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
12 February 2009