APAR status
Closed as program error.
Error description
smarteam inventor release checked-in parts of assembly error this customer has an issue with the release operation on Inventor products with derived parts. The client has assemblies containing derived components. It is however not possible to correctly release those checked-in parts of the assembly without errors. See steps below to reproduce the problem: Reproduce (SmDemo V5R18 SP6 - Inventor Professional 2008): ------------- Create an assembly containing checked in part and a checked in derived part: 1. Start Inventor Professional 2008 with SmarTeam integration 2. Inventor - New part 3. Inventor - SmarTeam save ('part1.ipt' created) 4. Inventor - New part (for the derived component) 5. Do not draw anything, immediately close sketch ("Return" button) 6. Choose derived component from the Part Features list 7. Choose the 'part1' (set scale factor to 2, to be able to easily distinguish the parts) 8. Inventor - SmarTeam save ('part2.ipt' created, this is the derived component) 9. Inventor - SmarTeam check in part1 10. Inventor - SmarTeam check in part2 11. Inventor - New assembly 12. Place component - smart desktop - 'part1' 13. Place component - smart desktop - 'part2' (the derived component) 14. Inventor - SmarTeam save 'assembly1.iam' 15. Inventor - File Open - Smart Desktop - choose part1 16. Inventor - SmarTeam Release part1 ==> Error message: SmartInventor "parameter is incorrect" (see attachment) This message is a bug. They can reproduce this problem in SmDemo with "derived parts", as described. It occurs with every derived part. The derived parts are not special ones. You can create whatever "derived part" you want, problem will occur. Just make sure that part2 is derived from part1. Could you correct this behavior? .
Local fix
Problem summary
smarteam inventor release checked-in parts of assembly error smarteam inventor release checked-in parts of assembly error this customer has an issue with the release operation on Inventor products with derived parts. The client has assemblies containing derived components. It is however not possible to correctly release those checked-in parts of the assembly without errors. See steps below to reproduce the problem: Reproduce (SmDemo V5R18 SP6 - Inventor Professional 2008): ------------- Create an assembly containing checked in part and a checked in derived part: 1. Start Inventor Professional 2008 with SmarTeam integration 2. Inventor - New part 3. Inventor - SmarTeam save ('part1.ipt' created) 4. Inventor - New part (for the derived component) 5. Do not draw anything, immediately close sketch ("Return" button) 6. Choose derived component from the Part Features list 7. Choose the 'part1' (set scale factor to 2, to be able to easily distinguish the parts) 8. Inventor - SmarTeam save ('part2.ipt' created, this is the derived component) 9. Inventor - SmarTeam check in part1 10. Inventor - SmarTeam check in part2 11. Inventor - New assembly 12. Place component - smart desktop - 'part1' 13. Place component - smart desktop - 'part2' (the derived component) 14. Inventor - SmarTeam save 'assembly1.iam' 15. Inventor - File Open - Smart Desktop - choose part1 16. Inventor - SmarTeam Release part1 ==> Error message: SmartInventor "parameter is incorrect" (see attachment) This message is a bug. They can reproduce this problem in SmDemo with "derived parts", as described. It occurs with every derived part. The derived parts are not special ones. You can create whatever "derived part" you want, problem will occur. Just make sure that part2 is derived from part1. Could you correct this behavior? .
Problem conclusion
THIS PROBLEM WILL BE FIXED ON SMARTEAM VERSION 5 RELEASE 19 SP03 LEVEL. - .
Temporary fix
Comments
APAR Information
APAR number
HD78814
Reported component name
SMARTEAM NT>XP
Reported component ID
569199970
Reported release
518
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-10-16
Closed date
2008-11-27
Last modified date
2008-11-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SMARTEAM NT>XP
Fixed component ID
569199970
Applicable component levels
R519 PSN
UP