DRAFTING(GENDRAFT)/ WRONG DISPLAY OF THREAD LINE. . SCENARIO: . 1. Start CATIA V5 2. Open the CATDrawing. 3. Select all View from tree. 4. Display the Properties by MB3. 5. Check the box for Thread, and click OK. . RESULTS OBTAINED: Thread is displayed only some part. . EXPECTED RESULTS: The thread lineshould be displayed correctly . .
Local fix
Problem summary
Problem conclusion
Temporary fix
Comments
THIS APAR IS CONSIDERED AS A SUGGESTION FOR IMPROVEMENT FOR CATIA. PLEASE CONTACT YOUR SUPPORT DEPARTMENT IN ORDER TO OPEN A REQUIREMENT FORM. INCIDENT DIAGNOSIS: . Drafting (GenDraft) / Wrong display of the Thread Line. . DEVELOPMENT REQUEST JUSTIFICATION: . The true problem here is the way threads are created. Tapered holes and screws are not a true geometry in the 3d design. It's just a data that figures on features ( holes or thread features). But the 3d geometry do not take it in account at all. To make appear those representations in the drawing, a temporary geometry is created on the fly during each view update. The problem with this geometry is that it makes a clash appear. Clashes are not officially supported by the projection engine. It is supported more or less depending on the situations. Here the thread trace (its projection) is just at the same depth than the border of the cut. . Depending on nearly nothing the trace is considered by the projection engine as seen or not. In the current state of the art it is impossible to do more without destabilizing other cases that are considered as more nominal. Answer and By-Pass As explained in the ppt provided in the materials the better by-pass is too move a bit the cutting body so as to avoid to get it exactly goes through the center axis of the hole. . BYPASS: . the better by-pass is too move a bit the cutting body so as to avoid to get it exactly goes through the center axis of the hole. . .
APAR Information
APAR number
HD75850
Reported component name
CATIA V5 WIN 64
Reported component ID
569165000
Reported release
517
Status
CLOSED SUG
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2008-07-04
Closed date
2008-07-11
Last modified date
2008-07-11
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
11 July 2008