IBM Support

HD73272: DMUKIN: "KINEMATICS SIMULATION" IS NOT PERFORMED AFTER THE EDIT .

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • ABSTRACT:
    DMUKIN: "KINEMATICS SIMULATION" IS NOT
    PERFORMED AFTER THE EDIT.
    .
    SCENARIO:
    1. Launch CATIA V5R18SP3 & open the
    file "TEST.CATProduct" with DMU Kinematics w/b.
    2. Expand "Applications" on the tree. "Mechanisms"
    is displayed on the tree.
    3. Expand "Mechanisms" on the
    tree. "Mechanism.1, DOF=0" is displayed on the
    tree.
    4. Double-click "Mechanism.1, DOF=0". "Kinematics
    Simulation" dialog box is displayed.
    5. Input 135 to the "Command.1" cell. Do not move
    a slider.
    6. Click "Close".
    7. Double-click "Mechanism.1, DOF=0".
    .
    RESULT:
    "Kinematics Simulation" is not performed.
    A "Kinematics Simulation" dialog box is displayed.
    The message which cannot perform a simulation is
    displayed. The insufficient message of the joint
    command is displayed.
    .
    EXPECTED RESULT:
    "Kinematics Simulation" should be performed even
    if the numerical value was inputted directly in the
    cell of dialog box.
    .
    

Local fix

Problem summary

  • DMUKIN: "KINEMATICS SIMULATION" IS NOT PERFORMED AFTER THE EDIT
    .
    ABSTRACT:
    DMUKIN: "KINEMATICS SIMULATION" IS NOT
    PERFORMED AFTER THE EDIT.
    .
    SCENARIO:
    1. Launch CATIA V5R18SP3 & open the
    file "TEST.CATProduct" with DMU Kinematics w/b.
    2. Expand "Applications" on the tree. "Mechanisms"
    is displayed on the tree.
    3. Expand "Mechanisms" on the
    tree. "Mechanism.1, DOF=0" is displayed on the
    tree.
    4. Double-click "Mechanism.1, DOF=0". "Kinematics
    Simulation" dialog box is displayed.
    5. Input 135 to the "Command.1" cell. Do not move
    a slider.
    6. Click "Close".
    7. Double-click "Mechanism.1, DOF=0".
    .
    RESULT:
    "Kinematics Simulation" is not performed.
    A "Kinematics Simulation" dialog box is displayed.
    The message which cannot perform a simulation is
    displayed. The insufficient message of the joint
    command is displayed.
    .
    EXPECTED RESULT:
    "Kinematics Simulation" should be performed even
    if the numerical value was inputted directly in the
    cell of dialog box.
    .
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN
    CATIA.
    Incident Diagnosis
    DMUKIN: 'KINEMATICS SIMULATION' IS NOT
    PERFORMED AFTER THE EDIT.
    Restriction Explanation
    The 135deg position is what we call a singular
    position. When exiting on this position and re-
    entering into the simulation command, the solver is
    not able to re-initialize the simulation anymore.
    This is a limitation of the kinematics solver.
    By-Pass
    You should stop at a position very close to 135 deg
    like 135.001 deg. Then the simulation can start
    again.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD73272

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    518

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2008-04-08

  • Closed date

    2008-05-30

  • Last modified date

    2008-05-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"518","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
30 May 2008