APAR status
Closed as Permanent restriction.
Error description
ASD : CONTEXTUAL DESIGN : CONTEXT IS LOST AFTER DOING MODIFICATION . 0.Start CATIA and make sure Tools\option Use root cotext in assembly is activated. 1.Open the attached Product 000126642. 2.Insert a new, empty part in the Product 000126646. 3.Activate the Part 000126647, select and copy the body.2 feature into the new created part with Paste Special As Result with link option. 4.Go to save management and save the product node 000126646. -Please note that the newly created part will be saved as well. 5.Close the main node 000126642 without Saving and reopen it. -Please note that the Contextual Link is active even now. 6.Now delete the newly created part. 7.Insert a new part at the same product node. 8.Activate the Part 000126647, select and copy the body.2 feature into the new created part with Paste Special As Result with link option. 9.Go to save management and save the product node 000126646. -Please note that the newly created part will be saved too. 10.Close the main node 000126642 without saving and reopen it. -Please note that the Contextual link has been lost now after the modification. . This is the problem. .
Local fix
Problem summary
ASD : CONTEXTUAL DESIGN : CONTEXT IS LOST AFTER DOING MODIFICAT ION ASD : CONTEXTUAL DESIGN : CONTEXT IS LOST AFTER DOING MODIFICATION . 0.Start CATIA and make sure Tools\option Use root cotext in assembly is activated. 1.Open the attached Product 000126642. 2.Insert a new, empty part in the Product 000126646. 3.Activate the Part 000126647, select and copy the body.2 feature into the new created part with Paste Special As Result with link option. 4.Go to save management and save the product node 000126646. -Please note that the newly created part will be saved as well. 5.Close the main node 000126642 without Saving and reopen it. -Please note that the Contextual Link is active even now. 6.Now delete the newly created part. 7.Insert a new part at the same product node. 8.Activate the Part 000126647, select and copy the body.2 feature into the new created part with Paste Special As Result with link option. 9.Go to save management and save the product node 000126646. -Please note that the newly created part will be saved too. 10.Close the main node 000126642 without saving and reopen it. -Please note that the Contextual link has been lost now after the modification. . This is the problem. .
Problem conclusion
THIS PROBLEM IS PERMANENT RESTRICTION IN CATIA. . Additional Information . The instance pointed as context is not saved, so the link has very little chance to be resolved again. The link will be OK in simple cases, but as soon as the scenario is more complex, the link will be lost. There is no solution to be able to correct this problem by code. . By-Pass . Save at level of definition of context, all Product Structure changes, before creating the contextual link.Use minimum context to avoid using "too high" level of Context. .
Temporary fix
Comments
APAR Information
APAR number
HD61127
Reported component name
CATIA V5 NT>XP
Reported component ID
569151000
Reported release
517
Status
CLOSED PRS
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2007-01-24
Closed date
2007-02-02
Last modified date
2007-02-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"517","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
02 February 2007