  • DMU Kinematics : The same Revolute joint cannot
    be define as input for more than one gear joint.
    Scenario :
    1 - open a CATProduct
    2 - Create 3 Revolute joints (Revolute 1 to 3)
    3 - Create a gear joint based on Revolute.1 and
    Revolute.2
    4 - Create a gear joint based on Revolute.2 abd
    Revolute.3
    --> It is not allowed to used Revolute.2 as input of
    the second gear joint.
    .
    

Local fix

Problem summary

  • DMU Kinematics : The same Revolute joint cannot be define as in
    put for more than one gear joint.
    DMU Kinematics : The same Revolute joint cannot
    be define as input for more than one gear joint.
    Scenario :
    1 - open a CATProduct
    2 - Create 3 Revolute joints (Revolute 1 to 3)
    3 - Create a gear joint based on Revolute.1 and
    Revolute.2
    4 - Create a gear joint based on Revolute.2 abd
    Revolute.3
    --> It is not allowed to used Revolute.2 as input of
    the second gear joint.
    .
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN
    CATIA
    .
    The problem submitted in batch mode and in
    interractive mode are not the same. It is not
    possible to use the same revolute for 2 different
    gear. The macro you send duplicate the revolute,
    the 2 items revolute even if they have same name
    are in fact 2 differents instances of the revolute.
    You can see that in analysing deeply the macro and
    see that the input in gear 1 and 2 are duplicate
    making a duplication of the revolute. To confirm
    this approch you can rename one of the revolute
    and you'll see that the second one will not be
    renamed as the internal ID are different.
    .
    This is so the same behaviour in interractive as in
    Macro and the normal behaviour is to not use twice
    the same revolute.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD52164

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    514

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-04-26

  • Closed date

    2006-05-05

  • Last modified date

    2006-05-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"514","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
05 May 2006