  • GSD / SHAPE FILLET FAILS WITH INTERNAL
    ERROR, BUT IT CAN B BE CREATED BY CLEARING
    SOME SELECTIONS
    .
    1. File -> Open the attached CATPart
    2. Click Shape Fillet icon and select as follow:
    Fillet Type: BiTangent Fillet
    Support 1 : Extrude.1
    Support 2 : Extrude.2
    Law Relimiter 2: Point.2
    ---> Both OK and Preview buttons become active.
    and click OK button
    ===> Then Update Error can be detected with
    message:
    Fillet.1: No entry found for error id 0x00000064.
    3. Click OK on the Update Error panel
    4. Click MB3 on Law Relimiter 1 -> Clear Selection
    5. Click MB3 on Law Relimiter 2 -> Clear Selection
    6. Click OK button
    ---> Then the shape fillet can be created.
    Remark:
    Same behavior can be detected at the modification
    of the Radius
    of the shape fillet as follow:
    1) Double click Fillet.1
    2) Change the Radius value from 10mm to 15mm
    ---> At this time, both OK and Preview buttons are
    inactive.
    3) Select as follow:
    Law Relimiter 2: Point.2
    ---> Both OK and Preview buttons become active.
    4) Click OK button
    ===> Then Update Error can be detected with
    message:
    Fillet.1: No entry found for error id 0x00000064.
    5) Click OK on the Update Error panel
    6) Click MB3 on Law Relimiter 1 -> Clear Selection
    7) Click MB3 on Law Relimiter 2 -> Clear Selection
    8) Click OK button
    ---> Then the shape fillet can be modified.
    EXPECTED RESULT:
    The shape fillet should be created without detecting
    the Update Error.
    

Local fix

Problem summary

  • GSD / SHAPE FILLET FAILS WITH INTERNAL
    ERROR, BUT IT CAN B BE CREATED BY CLEARING
    SOME SELECTIONS
    .
    1. File -> Open the attached CATPart
    2. Click Shape Fillet icon and select as follow:
    Fillet Type: BiTangent Fillet
    Support 1 : Extrude.1
    Support 2 : Extrude.2
    Law Relimiter 2: Point.2
    ---> Both OK and Preview buttons become active.
    and click OK button
    ===> Then Update Error can be detected with
    message:
    Fillet.1: No entry found for error id 0x00000064.
    3. Click OK on the Update Error panel
    4. Click MB3 on Law Relimiter 1 -> Clear Selection
    5. Click MB3 on Law Relimiter 2 -> Clear Selection
    6. Click OK button
    ---> Then the shape fillet can be created.
    Remark:
    Same behavior can be detected at the modification
    of the Radius
    of the shape fillet as follow:
    1) Double click Fillet.1
    2) Change the Radius value from 10mm to 15mm
    ---> At this time, both OK and Preview buttons are
    inactive.
    3) Select as follow:
    Law Relimiter 2: Point.2
    ---> Both OK and Preview buttons become active.
    4) Click OK button
    ===> Then Update Error can be detected with
    message:
    Fillet.1: No entry found for error id 0x00000064.
    5) Click OK on the Update Error panel
    6) Click MB3 on Law Relimiter 1 -> Clear Selection
    7) Click MB3 on Law Relimiter 2 -> Clear Selection
    8) Click OK button
    ---> Then the shape fillet can be modified.
    EXPECTED RESULT:
    The shape fillet should be created without detecting
    the Update Error.
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON Virtual Design  VERSION V5R17
    GA level.
    Additional Closure Information:
    THIS PROBLEM WILL BE FIXED ON CATIA VERSION
    5 RELEASE 17 GA level.
    .
    Incident Diagnosis
    GSD / SHAPE FILLET FAILS WITH INTERNAL
    ERROR, BUT IT CAN B BE CREATED BY CLEARING
    SOME SELECTIONS
    .
    Correction Explanation
    Variable shape fillet with infinite spine were not
    correctly managed.
    .
    Answer and By-Pass
    It is now possible to create fillet with infinite spine
    with constant radius law without specifing relimiters.
    Some additional test (versionned) has also been
    added:
    - if law is constant -> relimiters are not mandatory
    - if law is not constant -> relimiters are mandatory
    - if spine is infinite, we cannot define variable
    radius law.
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD48283

  • Reported component name

    CATIA V5 NT>XP

  • Reported component ID

    569151000

  • Reported release

    515

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-01-09

  • Closed date

    2010-09-01

  • Last modified date

    2010-09-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    CATIA V5 NT>XP

  • Fixed component ID

    569151000

Applicable component levels

  • R519 PSN

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"515","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
01 September 2010