IBM Support

HD48137: DMUNAV : CANNOT RECORD VIDEO TO AVI FILE USING DIVX CODEC.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as Permanent restriction.

Error description

  • DMUNAV : CANNOT RECORD VIDEO TO AVI FILE
    USING DIVX CODEC.
    SCENARIO:
    1. Open the CATProduct out of a directory on PC.
    2. Switch to workbench Digital Mockup - DMU
    Navigator.
    3. Select the sequence in the Applications of the
    CATProduct.Select Sequence.1.
    4. Select Icon for Simulation Player.Player is open.
    5. In Player Parameters (Ctrl+Shift+P) change
    sampling step to 0,2.
    6. Tools/Image/Video
    7. Setup Video-Rec change to requested directory
    Capture/activate document window/Movie/frames
    per sec.30.
    Activate Post Compression Mode
    Select Compressor Setup (Movie)
    Select DivX
    DivX Certified-Profile
    configure - High definition(=Profile)
    DivX Certified-Profile
    Videosequence  1024x768,
    Framerate 30
    Verschlチsselungsleistung - Standard
    bitrate - 8000MBit/s
    OK  (to all , only Video Rec left)
    8. Start Video Rec(see picture)
    9. Confirm with OK.
    10. Start Simulation.
    .
    RESULT:CATIA V5 can not record the simulation.
    .
    

Local fix

Problem summary

  • DMUNAV : CANNOT RECORD VIDEO TO AVI FILE USING DIVX CODEC.
    DMUNAV : CANNOT RECORD VIDEO TO AVI FILE
    USING DIVX CODEC.
    SCENARIO:
    1. Open the CATProduct out of a directory on PC.
    2. Switch to workbench Digital Mockup - DMU
    Navigator.
    3. Select the sequence in the Applications of the
    CATProduct.Select Sequence.1.
    4. Select Icon for Simulation Player.Player is open.
    5. In Player Parameters (Ctrl+Shift+P) change
    sampling step to 0,2.
    6. Tools/Image/Video
    7. Setup Video-Rec change to requested directory
    Capture/activate document window/Movie/frames
    per sec.30.
    Activate Post Compression Mode
    Select Compressor Setup (Movie)
    Select DivX
    DivX Certified-Profile
    configure - High definition(=Profile)
    DivX Certified-Profile
    Videosequence  1024x768,
    Framerate 30
    Verschl sselungsleistung - Standard
    bitrate - 8000MBit/s
    OK  (to all , only Video Rec left)
    8. Start Video Rec(see picture)
    9. Confirm with OK.
    10. Start Simulation.
    .
    RESULT:CATIA V5 can not record the simulation.
    .
    

Problem conclusion

  • THIS PROBLEM IS PERMANENT RESTRICTION IN
    CATIA.
    .
    Incident Diagnosis:
    DMUNAV : CANNOT RECORD VIDEO TO AVI FILE
    USING DIVX CODEC.
    .
    Restriction Explanation:
    This DIVX Codec doesn't support the API Video For
    Windows AVIStreamSetFormat, this call is
    supported by many others Codecs.
    .
    By-Pass:
    Use a DIVX Direct Show filter instead of this DIVX
    Video For Windows Codec.
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD48137

  • Reported component name

    ENOVIA DMU NT>X

  • Reported component ID

    569151800

  • Reported release

    514

  • Status

    CLOSED PRS

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2006-01-05

  • Closed date

    2006-02-03

  • Last modified date

    2006-02-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSEPME","label":"ENOVIA DMU"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"514","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
03 February 2006