APAR status
Closed as unreproducible in next release.
Error description
STCAI/ CGR files from SMARTEAM are not used for cache management in CATIA. ... Prerequire: Import customer database Put the attached files in the vault Create the cgrs for the CATParts in the vault with CreateCGRsInFolder.bat for example Work in visu mode in CATIA ... Scenario: 1. Create a CATIA Product in Catia V5. 2. Connect to SMARTEAM. 3.DO SMARTEAM/Assembly Management/ Insert Component 4.Select one of the Part that you previously put in the vault (eg Part_Test_1) 5.Save the Product 6.Check in it 7.Go in DMU Nav workbench and select Tools / Data Cache content 8.Delete the cgr of the Part 9.Select the Product in SMARTEAM and do MB3\File Operation\Open 10. Look in the cache folder for the cgr corresponding to the inserted Part Problem: according to the modification date the CGR was recomputed. .
Local fix
Problem summary
STCAI/ CGR files from SMARTEAM are not used for cache managemen t in CATIA. STCAI/ CGR files from SMARTEAM are not used for cache management in CATIA. ... Prerequire: Import customer database Put the attached files in the vault Create the cgrs for the CATParts in the vault with CreateCGRsInFolder.bat for example Work in visu mode in CATIA ... Scenario: 1. Create a CATIA Product in Catia V5. 2. Connect to SMARTEAM. 3.DO SMARTEAM/Assembly Management/ Insert Component 4.Select one of the Part that you previously put in the vault (eg Part_Test_1) 5.Save the Product 6.Check in it 7.Go in DMU Nav workbench and select Tools / Data Cache content 8.Delete the cgr of the Part 9.Select the Product in SMARTEAM and do MB3\File Operation\Open 10. Look in the cache folder for the cgr corresponding to the inserted Part Problem: according to the modification date the CGR was recomputed. .
Problem conclusion
Temporary fix
Comments
THE PROBLEM WAS SUBMITTED ON : CATIA VERSION 5 RELEASE 13. THIS PROBLEM IS NOT REPRODUCIBLE ON : CATIA VERSION 5 RELEASE 15 GA level AND ON V5R14SP06 AND V5R13SP10. Remark: please note that this incident is also corrected on V5R14SP5 and V5R13SP9. ... Incident Diagnosis In fact, there are no problem related to the cgr: The cgr file from SMARTEAM is really used by CATIA cache. But the problem was that the copy of the cgr did not keep creation/modification dates. ... Correction Explanation The correction consist in modifying the way copy is performed. Now it is performed with keeping dates (CATFCopy with last argument set to 1 = "cp -p") .
APAR Information
APAR number
HD32589
Reported component name
SMARTEAM NT>XP
Reported component ID
569199970
Reported release
513
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2004-12-22
Closed date
2005-03-14
Last modified date
2009-06-24
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
SMARTEAM NT>XP
Fixed component ID
569199970
Applicable component levels
R513 PSN
UP
R514 PSN SP51405
UP05/03/31 N 1000