HD27070: SHAPE DESIGN : CONTINUITY BETWEEN FILL SURFACE AND SUPPORT FACE IS NOT TANGENT

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as documentation error.

Error description

  • Shape Design : continuity between fill surface and
    support face is not tangent (APAR HD21867)
    .
    With tangency tolerance equal or inferior to
    0.5degree, CATIA considers that 2 faces which
    have an angular (angle) discontinuity <0.5deg
    are 'continuos in tangency' (G1)
    .
    If the checker result is <0.5deg, it means that
    CATIA will consider the faces as G1, but it is not
    true that all the geometry created above will be
    also a G1, some operators (like sweep, loft...) can
    spoil the quality.
    .
    About Fill Surface function, the tangent option of Fill
    does not create the surface of the smallest degrees
    by all possible, only creating the surface which has
    less than 0.5 degrees.
    In other words, even if the surface with 0 deg
    can be created mathematically, the surface which
    has less than 0.5 degrees is created.
    .
    .
    

Local fix

Problem summary

  • Shape Design : continuity between fill surface and support face
    is not tangent
    Shape Design : continuity between fill surface and
    support face is not tangent (APAR HD21867)
    .
    With tangency tolerance equal or inferior to
    0.5degree, CATIA considers that 2 faces which
    have an angular (angle) discontinuity <0.5deg
    are 'continuos in tangency' (G1)
    .
    If the checker result is <0.5deg, it means that
    CATIA will consider the faces as G1, but it is not
    true that all the geometry created above will be
    also a G1, some operators (like sweep, loft...) can
    spoil the quality.
    .
    About Fill Surface function, the tangent option of Fill
    does not create the surface of the smallest degrees
    by all possible, only creating the surface which has
    less than 0.5 degrees.
    In other words, even if the surface with 0 deg
    can be created mathematically, the surface which
    has less than 0.5 degrees is created.
    .
    .
    

Problem conclusion

  • THIS MODIFICATION WILL BE INCLUDED IN CATIA
    DOCUMENTATION DELIVERED WITH CATIA
    VERSION 5 RELEASE 15.
    NOTE THAT DOCUMENTATION WILL ALSO BE
    INCLUDED IN V5R14SP02.
    .
    Documentation Reference
    FreeStyle Shaper, Optimizer & Profiler User's Guide
    Basic Tasks, Analyzing Curves and Surfaces
    .
    MODIFICATION:
    In chapter Checking Connections Between
    Surfaces I added the following information:
    .
    When the minimal distance between two vertexes
    is inferior to 1 micron, the vertexes are merged
    and the surface is considered as continuous in point.
    .
    When the angle between two surfaces is inferior to
    0.5 degree, the surface is considered as continuous
    in tangency.
    .
    In chapter Checking Connections Between Curves,
    the following information is added :
    .
    When the minimal distance between two vertexes
    is inferior to 1 micron, the vertexes are merged
    and the curve is considered as continuous in point.
    .
    When the angle between two curves is inferior to
    0.5 degree, the curve is considered as continuous
    in tangency.
    .
    .
    

Temporary fix

Comments

APAR Information

  • APAR number

    HD27070

  • Reported component name

    CATIA V5/NT/200

  • Reported component ID

    569151000

  • Reported release

    512

  • Status

    CLOSED DOC

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2004-08-26

  • Closed date

    2004-10-01

  • Last modified date

    2004-10-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"512","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
01 October 2004