Error description
Prob: DMUKIN - Gear Joint : Cannot select 2nd Revolute Joint. Operation: 1. Open CATProduct 2. Click Gear Joint icon 3. Revolute Joint 1 : Revolute.2 Revolute Joint 2 : Revolute.3 --> Cannot select Revolute Joint 2 . Remk: If selecting: Revolute Joint 1 :Revolute.3 Revolute Joint 2 :Revolute.2 This problem also occurs. This problem does not occur on OK data. . .
Local fix
Problem summary
Incident Diagnosis DMUKIN - Gear Joint : Cannot select 2nd Revolute Joint Correct Application The 2 revolute joints must contain a common part. This is not the case in the customer exemple. The documentation has been updated in R12 to give this precision Documentation Reference DMU Kinematics Simulator Basic Tasks Gear joints
Problem conclusion
Temporary fix
Comments
Incident Diagnosis DMUKIN - Gear Joint : Cannot select 2nd Revolute Joint Correct Application The 2 revolute joints must contain a common part. This is not the case in the customer exemple. The documentation has been updated in R12 to give this precision Documentation Reference DMU Kinematics Simulator Basic Tasks Gear joints
APAR Information
APAR number
HD08114
Reported component name
ENOVIA DMU NT/2
Reported component ID
569151800
Reported release
508
Status
CLOSED USE
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2003-06-20
Closed date
2003-07-11
Last modified date
2003-07-22
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CATIA V5/NT/200
Fixed component ID
569151000
Applicable component levels
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"508","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
22 July 2003