IBM Support

HC99275: TEAM PDM: CAN'T DELETE PARAMETER FROM DRAWING ONCE IT IS MAPPED TO ST

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • TEAM PDM: Can't delete parameter  from Drawing once it is
    mapped to ST
    Sceanario:
    1) Open CATIA, Connect to Smarteam to SmCATIA database as
    joe
    2) Create new Drawing from File->New menu
    3) Save Drawing on local hard drive
    4) Save Drawing to Smarteam, enter "ST Description" in the
    Description fields of Drawing and Sheet objects
    5) Switch Drawing to the background view and add text
    "Background Text"
    6) Map the text to Smarteam's Description attribute using
    TeamPDM->Properties->Map a Text Value.. Select mapping to be
    bidirectional (update property and update TeamPDM)
    7) Update text in the drawing from Smarteam by invoking
    TeamPDM->Properties->Load from database. Now the value of
    text in the drawing has changed from "Background Text" to
    "ST Description"
    8) Delete parameter by right-clicking on Description
    parameter in the left pane of Drawing window and selecting
    Delete from the pop-up menu.
    9) The following message will pop up: "You can only delete
    the new parameters that you have added to the part; the
    parameters created for each feature can be deleted only by
    deleting the feature itself"
    

Local fix

Problem summary

  •  INCIDENT DIAGNOSIS:
      The creation of f(x) parameter during the execution of the
      command "Map a Text Value" was badly done.
      That's why it was not possible to delete it.
    
     TECHNICAL EXPLANATION FOR THE CORRECTION:
      Now, the creation makes something that is close to what a
      user would have done manually.
      Thus, the result is the same as if the operation has been done
      manually:
       .If he wants, the user can erase the knowledge parameter.
       .After that, the text looses its link and becomes "Isolated"
    
     ANSWER AND POSSIBLE BY-PASS:
      The only by-pass before this correction was to delete all the
      parameters (by selectionning delete on "Parameters" node.
    

Problem conclusion

  • THIS PROBLEM WILL BE FIXED ON
      CATIA VERSION 5 RELEASE 11 GA level.
    NOTE THAT THIS PROBLEM WILL ALSO BE FIXED ON V5R10SP01 and
     V5R9SP05
    

Temporary fix

Comments

APAR Information

  • APAR number

    HC99275

  • Reported component name

    CATIA V5/NT/200

  • Reported component ID

    569151000

  • Reported release

    509

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2002-10-04

  • Closed date

    2002-10-28

  • Last modified date

    2002-12-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    FILE
    

Fix information

  • Fixed component name

    CATIA V5/NT/200

  • Fixed component ID

    569151000

Applicable component levels

  • R509 PSN SP50905

       UP02/11/19 I 1000

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSVJ2K","label":"CATIA V5"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"509","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: